System Installation Guide
12
69-2688—01  I/O-CHTSTAT03
Installer options (ISU)
6
Create Setup: Press CREATE SETUP to set all system settings one 
by one.
View/Edit Current Setup: Press VIEW/EDIT CURRENT SETUP to 
select a specific function and make quick changes.
ComfortNet User Menu: Press COMFORTNET USER MENU to view 
equipment information.
Installer Test: Press INSTALLER TEST to quickly determine if the 
heat, cool, fan and thermostat are operating properly. Minimum off 
timers are ignored during the test.
Data Logs: Press DATA LOGS to view the Alerts Log and User
Interactions Log.
Wireless Device Manager: Press WIRELESS DEVICE MANAGER 
to add or remove wireless accessories.
Advanced Options: Press ADVANCED OPTIONS to setup the 
thermostat using a USB device or to restore the thermostat to the
factory default settings.
TIP: You can use the thermostat USB port to download all system configuration and installer options, including your company
name and contact information. You can upload this data to each thermostat you install, to save time.
To setup the thermostat, press
MENU and scroll down to press INSTALLER OPTIONS
Enter the date code (password) when prompted. The date code is printed on the
back of the thermostat; or press
MENU > EQUIPMENT STATUS to find the date code. 
After you enter the password, press
CREATE SETUP to setup the thermostat.
A brief summary of installer options follows. You can download a complete list of
all options at http://customer.honeywell.com.
1000 Language 
B
1010 Residential/Commercial 
B
1030 
Device Name 
B
1030 
Device Name on Home Screen 
C
1040 Programmable/Non-programmable 
B
1050 Fahrenheit/Celsius 
B
1060 
Outdoor Air Sensor 
B
2000 
Heating System Type 
B
2010 
Heating Equipment Type 
B
2070 
Heat Stages 
B
2070 
Cool/Compressor Stages 
B
2070
Backup Heat Stages
B
2180
Backup Heat Type
B
3000 
Manual/Auto Changeover 
B
3000 
Auto Changeover Deadband 
B
3010 
Temperature Control Options 
B
3020 
Finish With High Cool Stage 
B
3021 
Finish With High Heat Stage 
B
3030 
Staging Control - Cool Differentials 
B
3050-3060  Staging Control - Heat Differentials 
B
3090
Staging Control - Backup Heat Differentials
B
3110
Backup Heat Upstage Timer
B
3120 
Outdoor Compressor Lockout 
B
3120
Outdoor Backup Heat Lockout
B
3140 
Cool/Compressor Cycles Per Hour 
B
3150 
Heat Cycles Per Hour 
B
3160
Backup Heat Cycles Per Hour
B
3170-3190  Cooling Derivative, Integral, Throttling range 
C
3200-3220  Heating Derivative, Integral, Throttling range 
C
3240 
Minimum Compressor Off Time 
B
3260 
Extended Fan Run Time in Cool 
B
3260 
Extended Fan Run Time in Heat 
B
4000 
Number of Schedule Periods 
B
4010 
Pre-occupancy Purge Duration 
C
4020 
Override: Standard or Initiate Occupancy 
C
4030 
Override Duration 
C
4050 
Minimum Recovery Settings - Heat 
C
4060 
Maximum Recovery Settings - Heat 
C
4070 
Minimum Recovery Settings - Cool 
C
4080 
Maximum Recovery Settings - Cool 
C
4090 
Adaptive Intelligent Recovery 
R
4100 
Minimum Cool Setpoint 
B
4100 
Maximum Heat Setpoint 
B
4110 
Keypad Lockout 
B
4120 
Entry/Exit Remote -  
Home/Occupied Cool Setpoint 
B
4120 
Entry/Exit Remote -  
Home/Occupied Heat Setpoint 
B
 ISU 
Function 
ISU 
Function
R
: Residential 
C
: Commercial 
B
: Both