CTK03 ComfortNet™ Communicating Thermostat
13
I/O-CHTSTAT03  69-2688—01
ComfortNet User Menu 
Press
MENU > INSTALLER OPTIONS > COMFORTNET USER MENU
Additional equipment information is found in the ComfortNet User Menu.
Press
MENU and scroll down to press INSTALLER OPTIONS. Enter the date code
(password) when prompted. The date code is printed on the back of the
thermostat; or press
MENU > EQUIPMENT 
STATUS to find the date code.
After you enter the password, press
COMFORTNET USER MENU and then select 
the equipment type (furnace, air handler,
air conditioner, heat pump) to view the
specifications. 
Each equipment type is divided into
categories which include:
4130 
Entry/Exit Remote -  
Away/Unoccupied Cool Setpoint
B
4130 
Entry/Exit Remote -  
Away/Unoccupied Heat Setpoint
B
4140 
Entry/Exit Remote -  
Vacation/Holiday Cool Setpoint 
B
4140 
Entry/Exit Remote -  
Vacation/Holiday Heat Setpoint 
B
5040
Indoor Sensors Used for Temperature Control
B
7000 
Filter Type 
B
7020 
Number of Air Filters 
B
7110 
Air Filter Replacement Reminder 
B
7110 
Air Filter 2 Replacement Reminder 
B
7120 
EAC Cell Cleaning Reminder 
B
7120 
EAC Pre-Filter Cleaning Reminder 
B
7120 
EAC Post-Filter Replacement Reminder 
B
8000 
Humidifier Type 
B
8010
Indoor Sensor Used for Humidification Control
B
8050 
Humidification - Window Protection 
B
8060 
System Modes Allowing Humidification 
B
8070 
Humidification Control 
B
8100 
Clean Tank / Water Filter Replacement Reminder 
B
8100 
Humidifier Pad Replacement Reminder 
B
9000 
Dehumidification Equipment 
B
9010
Indoor Sensor Used for Dehumidification Control
B
9020 
Humidity Sensor Displayed on the Home Screen 
B
9070 
Dehumidification - Overcooling Limit 
R
9080 
Dehumidification Control 
C
9090 
Dehumidification Minimum On Time 
C
9100 
High Humidity Comfort Reset Setting 
C
9180 
Dehumidification Away Mode 
B
9190 
Dehumidification Away Mode - Fan Control 
B
9200 
Dehumidification Away Mode -  
Low Limit Temperature 
B
9200 
Dehumidification Away Mode -  
Temperature Setting 
B
9200 
Dehumidification Away Mode -  
Dehumidification Setting 
B
9210 
Dehumidifier Filter Replacement Reminder 
B
10000 
Ventilation Type 
B
10050 
Ventilation Control Method 
B
10090
Number of Bedrooms
R
10090 
Size of House 
R
10100 
Enter Equipment Ventilation Rate 
R
10120 
Ventilation Percent On Time 
B
10170 
Ventilator Filter Cleaning Reminder 
B
11000
Number of UV Devices
B
11050
UV Bulb Replacement Reminder
B
11050
UV Bulb 2 Replacement Reminder
B
12000 
Installer Custom Reminders 
B
14000 
Clock Format 
B
14010 
Daylight Saving Time 
B
14020 
Indoor Temperature Display Offset 
B
14020 
Indoor Humidity Display Offset 
B
15000-15020 Dealer name, phone, email, website, message 
B
Installer options (ISU)
6
 ISU 
Function 
ISU 
Function
Configuration: Provides information regarding the setup of the equipment. An example of configuration data is the number 
of cooling stages for an AC condensing unit.
Diagnostics: Provides a fault history of the equipment and allows the installer to clear the fault history.
Identification: Provides the model and serial number of the equipment and software revision information.
Sensors: Provides the sensor data of the equipment. In some instances, it may allow the installer to setup or turn off a 
sensor.
Setup: Allows the installer to change the settings of the equipment.
Status: Provides the current status of the equipment.
The following pages provide submenus of the above categories for each
equipment type that may be used with this thermostat.