Everspring Industry Co Ltd ST814 Manuale Utente

Pagina di 8
 
2
1
2
 Plastic Wall Plug
 
3
4
Note: Auto inclusion timeout is 4 minutes during which the node information of 
explorer frame will be emitted once every 5 seconds.  Unlike “inclusion” 
function as shown in the table below, the execution of auto inclusion is free from 
pressing the 
 key.  
 
The table below lists an operation summary of basic Z-Wave functions.    Please 
refer to the instructions for your Z-Wave
TM
 Certificated Primary Controller to 
access the setup function, and to include/exclude/associate devices. 
 
Function Description
LED 
Indication
No node ID 
The Z-Wave Controller does not allocate 
a node ID to the detector. 
The RF reading displays 
00 (MODE 7)   
 
Inclusion 
1. Have Z-Wave Controller entered 
inclusion mode. 
   flashes 
2. Pressing        key 3 times within 
1.5 seconds will enter inclusion mode.
 
Exclusion 
1. Have Z-Wave Controller entered 
exclusion mode. 
   flashes 
2. Pressing         key 3 times within  
1.5 seconds will enter exclusion mode 
Node ID has been excluded 
The  RF  reading  displays 
00 (MODE 7) 
 
Reset 
1. Pressing         key 3 times within 
1.5 seconds will enter inclusion mode
 
   flashes 
2. Within 1 second, press         key 
again and hold it until long beep tone 
is off
 
3. Node ID has been excluded, restores 
to factory default.
 
The RF reading displays 
00 (MODE 7) 
 
Association 
1. Have Z-Wave Controller entered   
association mode. 
 flashes 
2. Pressing         key 3 times within  
1.5 seconds will enter association 
mode 
3. There are two groupings – 1 and 2.   
Refer to Z-Wave’s Groupings as 
described on page 5. 
 
 Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a node ID 
allocated by Z-Wave Controller means exclusion. 
 Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.
 
Choosing a Suitable Location 
 
The Temp./Humid. Detector can either be mounted on a wall or can be 
freestanding on a table.    Please consider a most suitable way before mounting/ 
placing it. 
Wall Mounting 
 
1.  Place mounting bracket over a desired location on the wall.    Through the 2 
screw holes of the bracket, mark the mounting surface with a pencil. 
 
2.  Where marked, drill holes into mounting surface using an appropriate size 
drill bit and insert the plastic wall plugs supplied respectively. 
 
3.  Screw mounting bracket onto the mounting surface.  Ensure that the 
screws are flush with the bracket. 
 
4.  Snap the Temp./Humid. Detector into place on the mounting bracket. 
 
5.  Secure with the fixing screw supplied. 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 1   
 
 
        FIGURE 2 
 
Table Placing 
 
1.  Insert the stand into the hole on mounting bracket and turn 90 degrees 
clockwise. 
 
2.  Once snapped in place, the detector can be placed on a shelf, table or other 
surface where the temperature and humidity measurements are desired. 
 
 
 
 
 
 
 
FIGURE3 
    
 
 
FIGURE 
 
Note: Take care when fixing the detector to a metal surface, or mounting within 
1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio 
range of the device.