Everspring Industry Co Ltd ST814 Manuale Utente
2
1
2
Plastic Wall Plug
3
4
5
Note: Auto inclusion timeout is 4 minutes during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion”
function as shown in the table below, the execution of auto inclusion is free from
pressing the
explorer frame will be emitted once every 5 seconds. Unlike “inclusion”
function as shown in the table below, the execution of auto inclusion is free from
pressing the
key.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-Wave
TM
Certificated Primary Controller to
access the setup function, and to include/exclude/associate devices.
Function Description
LED
Indication
No node ID
The Z-Wave Controller does not allocate
a node ID to the detector.
a node ID to the detector.
The RF reading displays
00 (MODE 7)
00 (MODE 7)
Inclusion
1. Have Z-Wave Controller entered
inclusion mode.
flashes
2. Pressing key 3 times within
1.5 seconds will enter inclusion mode.
Exclusion
1. Have Z-Wave Controller entered
exclusion mode.
flashes
2. Pressing key 3 times within
1.5 seconds will enter exclusion mode
Node ID has been excluded
The RF reading displays
00 (MODE 7)
00 (MODE 7)
Reset
1. Pressing key 3 times within
1.5 seconds will enter inclusion mode
flashes
2. Within 1 second, press key
again and hold it until long beep tone
is off
is off
3. Node ID has been excluded, restores
to factory default.
The RF reading displays
00 (MODE 7)
00 (MODE 7)
Association
1. Have Z-Wave Controller entered
association mode.
flashes
2. Pressing key 3 times within
1.5 seconds will enter association
mode
3. There are two groupings – 1 and 2.
Refer to Z-Wave’s Groupings as
described on page 5.
described on page 5.
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID
allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.
Choosing a Suitable Location
The Temp./Humid. Detector can either be mounted on a wall or can be
freestanding on a table. Please consider a most suitable way before mounting/
placing it.
freestanding on a table. Please consider a most suitable way before mounting/
placing it.
Wall Mounting
1. Place mounting bracket over a desired location on the wall. Through the 2
1. Place mounting bracket over a desired location on the wall. Through the 2
screw holes of the bracket, mark the mounting surface with a pencil.
2. Where marked, drill holes into mounting surface using an appropriate size
drill bit and insert the plastic wall plugs supplied respectively.
3. Screw mounting bracket onto the mounting surface. Ensure that the
screws are flush with the bracket.
4. Snap the Temp./Humid. Detector into place on the mounting bracket.
5. Secure with the fixing screw supplied.
FIGURE 1
FIGURE 2
Table Placing
1. Insert the stand into the hole on mounting bracket and turn 90 degrees
clockwise.
2. Once snapped in place, the detector can be placed on a shelf, table or other
surface where the temperature and humidity measurements are desired.
FIGURE3
FIGURE
4
Note: Take care when fixing the detector to a metal surface, or mounting within
1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio
range of the device.
1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio
range of the device.