 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions 
 
 
GENERAL INFORMATION
 
The Honeywell 5800-OD Wireless Outdoor Motion Sensor 
(referred to as the 5800-OD) combines the convenience of wireless 
technology with a full featured outdoor PIR motion sensor.  The 
major features are highlighted below: 
ƒ
 
Immunity to bright light 
disturbances from headlights, 
sunlight, and other bright 
light sources. 
ƒ
 
Very low current draw. 
ƒ
 
Discriminates both large and 
small animals to reduce false 
alarms. 
ƒ
 
Selectable detector 
range and angle. 
ƒ
 
Battery saving circuit allows 
for a 5 or 120 second period of 
inactivity before being 
reactivated. 
ƒ
 
Tamper detection. 
 
SPECIFICATIONS 
Detection Method 
Passive Infrared 
Initial Warm Up 
~ 2 minutes 
Mounting Height 
0.8 - 1.2m (2.7 - 4ft) wall or pole 
 
 
Range 
Adjustable up to 12m (40ft) 
Pattern 
90° pattern consisting of 13 zones.  This 
pattern can be adjusted in 15° incre-
ments from center up to 45°.   
Sensitivity 
2.0° C at 0.6m/s (3.6° F at 2.0ft/s) 
Detection Speed 
0.3 - 1.5m/s (1 - 5ft/s) 
Operating Voltage 
6 VDC (uses 4 lithium 1.5VDC AA cells) 
Current 
3mA max (during walk test) 10uA 
(standby) 
Battery Saving Timer 
Adjustable 120sec or 5sec 
Alarm Period 
~ 2.5 seconds 
LED Indicator 
Enabled during a walk test. 
Disabled for normal operation. 
Weatherproof 
IP54 compliance 
Operating Temperature 
– 20 to + 50 ° C (– 4 to +122° F) 
Humidity 
95% Max 
Accessories (included) 
Pole mounting kit, screw kit, detection 
masking strips.  
 
 
 
 
INSTALLATION (refer to the Component Identification Diagram on page 5)
 
 1 
  
Select the Mounting Position
 
‰
 
Avoid strong sunlight into the sensor's field. 
‰
 
Avoid moving or swaying trees and bushes. 
‰
 
Orient the detector 
so that intrusion 
passes across the 
detection field, not 
into the sensor. 
 
 
 
 
‰
 
Allow 110mm (4.4") 
above the sensor to 
enable  opening the 
cover.  
‰
 
Choose an installation 
height of 0.8m to 1.2m 
(2.7 to 4ft).   
‰
 
Ensure the sensor can be 
mounted on a perpendicular 
wall or pole that would make 
its detection pattern parallel 
to the ground. 
 
Parallel
 
 2 
  
Prepare the Sensor for Mounting
 
1. 
Loosen the Captive Lock 
Screw and remove the 
Cover. 
 
2. 
Remove the four (4) screws fastening the Detector 
to the Back Box. 
 
 
3. 
Remove Detector from the Back Box. 
 
 
 3 
 
 
Install / Replace the Battery
 
IMPORTANT: 
ƒ
 
Use only lithium batteries. 
ƒ
 
Use four (4) lithium 1.5VDC AA cells.  (Energizer L91 or 
equivalent.) 
ƒ
 
Observe polarity. 
ƒ
 
Mark the date of replacement on the batteries. 
1. 
If necessary, loosen the 
Captive Lock Screw and lift 
Cover off.  Then, remove 4 
screws that secure the 
Detector to the Back Box. 
2. 
Observe the proper polarity 
and replace the batteries.  
Ensure positive side of 
battery is pointing away from 
the springs.
 
3. 
For reference, mark the date of 
replacement on the batteries. 
 
 
 
PLEASE GO TO PAGE 6 FOR FCC / IC STATEMENTS