Honeywell International Inc. 8DL5800PIR-OD Manuale Utente
5800-OD Wireless Outdoor Motion Sensor – Installation Instructions
–
3
–
Press and slide the Detection Length Adjustment Switch to the desired position.
A
B
C
D
MAX DETECTION LENGTH
POSITION
STANDARD ENVIRONMENTAL
Á
D
0
2.0m (6.7ft)
1.5 - 2.5m (5 - 8ft)
C
0
5.0m (16.7ft)
0
4 - 5.5m (13 - 18ft)
B
0
8.0m (26.7ft)
0
6 - 10m (20 - 33.3ft)
A
12.0m (40.0ft)
10 - 15m (33.3 - 50ft)
Á
Detection length may vary due to environmental conditions.
Detection height = 1m (3.3ft)
SET THE DETECTION AREA ANLGLE
1.
The detection area angle is 90° with 7
fingers as shown.
fingers as shown.
90
o
45
o
45
o
Top view
0
12
10
5
5
12
12
0
10
10
5
(m)
(m)
45 Adjustable
Active detection
fingers.
fingers.
o
45 Adjustable
o
2.
Hold the sensor and turn it to the desired
direction. Each click represents 15° of
change.
change.
Adjust to
desired direction
IF NECESSARY, CONFIGURE DETECTION MASKING
1.
Spread the Cover and gently press on the
Lens to remove the Lens Holder.
Lens to remove the Lens Holder.
2.
Separate the Lens from the Cover.
Cover
Lens
Area Masking
Plate
Plate
Lens
Holder
Holder
3.
Identify the segments on the Lens to be masked.
4.
Then apply the adhesive Masking
Strip(s), as necessary, inside the
lens to cover the desired
segments.
Strip(s), as necessary, inside the
lens to cover the desired
segments.
1
13
2
3
4
5
6
7
8
9
10
12
11
1
13
2
3
4
5
6
7
8
9
10
12
11
5.
Replace the Lens by aligning the 4 cutouts
on the lens to the 4 projections on the cover.
Snap in place with the Lens Holder.
on the lens to the 4 projections on the cover.
Snap in place with the Lens Holder.
Cover
Lens
6.
Ensure the Lens Holder is held by the left and
right cover prongs and the two tabs are engaged.
right cover prongs and the two tabs are engaged.
Cover
Lens
Holder