Honeywell International Inc. 8DL5821 Manuale Utente

Pagina di 4
PROGRAMMING THE UNIT 
Prior to programming the device you must choose an 
operating mode.  Refer to Table 1 for the applicable 
operating mode.  The transmitter’s serial number must be 
enrolled in the control panel before it will function in the 
system.  When programming this transmitter at the control, 
note the following:   
•  Input Type = 3 (Supervised RF) 
•  Loop number = 1, 2, 3, or 4 
•  Each loop # requires one zone.   
1.  Install the battery (if not already installed).  Observe 
polarity!   
2.  Enter the control’s programming mode.   
3.  Enter the zone number to be programmed.   
4.  Transmit from the detector when prompted by pressing 
the tamper switch.   
5.  When the serial number is displayed transmit from the 
detector by pressing the tamper switch.   
The current loop number will begin to flash.   
6.  Enter the desired loop number manually.   
7.  Test the detector after enrolling into the system.  Refer 
to the Testing section.   
5821-001-V0
LOCKING
TAB
RELEASE
WINDOW
COVER PRY-OFF SLOT
MOUNTING
PLATE
HOLES (2)
OBSER
VE POLARITY
LOCKING
TAB
WIRES
MOUNTING PLATE
CASE
COVER
RETAINING
HOOKS
(3)
POST (2)
 
5821-002-V0
LOOP
TERMINALS
LITHIUM BATTERY
CR1-335                  (3V)
COVER
RETAINING
HOOKS (3)
ANNTENNA
DIP SWITCH
+ +
COVER 
PRY-OFF
SLOT
WIRE ENTRY
HOLE
TAMPER
SWITCH
IC
CRYSTAL
+
_
2
1
ON
 
MOUNTING THE DETECTOR 
You can mount the 5821 on a wall or ceiling within the 
protection area:   
•  The 5821 may be installed in any direction.   
•  When used in-conjunction with the ADEMCO 470PB 
probe flood sensor, use no more than 12 inches of wire 
from the 5821 to the flood sensor.   
•  When used in-conjunction with ADEMCO T280R 
temperature probe, use the shortest wire possible to 
improve sensitivity.   
•  Although the unit can be mounted directly to a surface, 
we recommend that the mounting plate be used, for 
ease in removing the unit for servicing should it become 
necessary.  
•  Avoid mounting the detector near heat generating 
devices (e.g. ovens, heat vents, furnaces, boilers) or to a 
metal cabinet.   
IMPORTANT:  This detector should be used for property 
protection.  Reliance should not be placed on 
this detector for life safety.  When life safety 
is involved, smoke detectors MUST also be 
used.  The detector and its optional probes 
must not be painted.   
Wireless Transmission Path Test 
A good RF transmission path must be established from the 
proposed mounting location before permanently installing 
the detector.  To determine that there is good signal 
reception from the proposed location, perform the test 
procedure described in TESTING THE DETECTOR section.   
Once a good RF transmission path is confirmed, mount the 
detector as follows:  
1.  Remove the battery.   
2.  Disengage the attached mounting plate from the case 
by inserting the blade of a small screwdriver into the 
locking tab release window (see Figure 1) and pressing 
it against the locking tab (also shown in Figure 1), 
while sliding the mounting plate upward along the case 
back until free.   
3.  Install the mounting plate, with its two case- holding 
posts pointing up (in this example), in the location 
selected.  Use the flat-head screws supplied.   
4.  For surface wiring entry, two thin "breakout" areas are 
provided in the case wall (see Figure 1).  
5.  Attach the case back to the mounting plate by sliding 
the keyhole slots in the case back down onto the 
mounting plate's case holding posts. The locking tab 
will click as the case back locks in place. 
EXTERNAL PROBE WIRING CONNECTIONS
 (If used) 
6.  With the battery still not inserted, connect the wires to 
the unit's loop terminals (see Figure 2). 
7.  Install the battery.   
TESTING THE DETECTOR 
The test procedure should be performed to determine a good 
RF transmission path and again after installation is 
completed.   
Activate the control panel’s test mode.   
Activate the detector:   
The system’s keypads should beep and the detectors ID 
should be displayed.   
Exit the control’s test mode.   
MAINTAINING PROPER OPERATION 
To maintain the detector in proper working condition, it is 
important that you observe the following:   
Replace the battery when the system indicates that the 
5821 has reported a low battery condition.   
Units should never be relocated without the advice or 
assistance of the alarm service company.