Data Field Descriptions 
 
 
SYSTEM STATUS REPORT CODES (
60–
69) 
 
 
60
 
Trouble Report Code  
(See notes above) 
This will be sent if a zone goes into trouble. 
61
 
Bypass Report Code  
(See notes above) 
This will be sent when a zone is manually bypassed. 
62
 
AC Loss Report Code  
(See notes above) 
Timing of this report is random with up to a 4-hour delay. If AC restores 
before the report goes out, there is no AC restore report. 
 
63
 
Low Battery Report Code  
(See notes above) 
This will be sent when a low battery condition exists in the system’s 
standby battery. 
 
64
 
Test Report Code  
(See notes above) 
This is sent periodically to test that the communicator and phone lines are 
operational (frequency of report is selected in field 
51). 
 
Note: The control  validates the data entered in this field. If the selection 
is not valid the control will emit a single long beep indicating that 
the selection has been rejected. The control replaces the selection 
with the default value which is displayed on the keypad. 
 
65
 
Open Report Code  
(See notes above)
 
This is sent upon disarming of the system. 2nd digit = user number, if 
expanded or 4+2 reporting is selected. 
 
66
 
Arm AWAY/STAY Report Code  
(See notes above)
 
This option allows for independent programming of AWAY and STAY 
reports. 2nd digit of report is user number if expanded or 4+2 reporting is 
selected. 
Note: OPEN reports are not sent if the associated closing report is not 
enabled. 
 
67
 
RF transmitter Low Batt. Report Code 
(See notes above) 
This is sent in the event that a wireless transmitter low battery condition 
exists. 
68
 
Cancel Report Code 
(Always enabled, a report code can be entered if 
reporting formats other than Contact ID 
® 
are used) 
This is sent upon disarming of the system after an alarm condition was 
reported. 
 
Note:   The control  validates the data entered in this field. If the 
selection is not valid the control will emit a single long beep 
indicating that the selection has been rejected. The control 
replaces the selection with the default value which is displayed on 
the keypad. 
 
69
 
Recent Closing Report 
(This feature is always enabled. A report code can be 
entered if formats other than Contact ID 
® 
are used)
 
Sent when an alarm occurs within two minutes after exit delay expires. 
Disarming the system within the two minutes stops the alarm sound and 
the keypad displays the faulted zone number (and will display “CA” if 
cancel display option in field *57 is enabled.)  No messages are sent to the 
Central Station. 
 
If the system is not disarmed within two minutes, the alarm sound 
continues and a “Recent Closing” and a “Zone Alarm” message are sent to 
the Central Station (after dial delay expires). 
 
Note: The control  validates the data entered in this field. If the selection 
is not valid the control will emit a single long beep indicating that 
the selection has been rejected. The control replaces the selection 
with the default value which is displayed on the keypad. 
 
 
RESTORE REPORT CODES (
70–
76)
70
 
Alarm Restore Report Code, 1st Digit 
(See notes above)
 
Sent when the zone that caused an alarm is restored to its non-faulted 
condition. 2nd digit is automatically sent as the 2nd digit of the zone 
alarm report code programmed in field 
56, if expanded or 4+2 reporting 
is selected. 
 
71
 
Trouble Restore Report Code 
(See notes above)
 
 
Sent when a trouble in a zone is restored. 
72
 
Bypass Restore Report Code 
(See notes above)
 
 
Sent when a zone that has been bypassed is unbypassed. 
73
 
AC Restore Report Code 
(See notes above) 
 
Sent when AC power has been restored after an AC power outage. 
 
74
 
Low Battery Restore Report Code 
(See notes above)
 
 
Sent when a system low battery condition is restored to normal.