Replacement (Subtask 23-20-59-000-013-A01)
(1)
Slide the RTA-50D VDR onto the tray of the mount and then gently push the RTA-50D VDR
until the guide pins are aligned and the connectors make a firm connection.
(2)
Tighten the two knurled screw clamps located on the front of the mount until they are firmly
seated over the hold-down hooks located on the front of the RTA-50D VDR.
(3)
Safety wire the two knurled screw clamps.
9.
Maintenance Procedures (TASK 23-20-59-000-808-A01)
A.
Adjustments and Alignments (Subtask 23-20-59-000-014-A01)
(1)
There are no adjustments or alignments required for the RTA-50D VDR. All alignment and
adjustment procedures are accomplished during bench maintenance. The technician must
remove the unit from the aircraft and reference must be made to the related maintenance
manual when unit performance indicates an adjustment or an alignment is required.
B.
System Protection (Subtask 23-20-59-000-015-A01)
(1)
The system must be protected by a 10-AMP circuit breaker located at the circuit breaker
panel in the aircraft.
C.
Lubrication Practices (Subtask 23-20-59-000-016-A01)
(1)
There are no requirements for lubrication of any RTA-50D VDR components.
D.
Cleaning (Subtask 23-20-59-000-017-A01)
(1)
When deemed necessary, depending on the environment to which the equipment is exposed
and the intensity of use, periodic cleaning can be performed. Any dust on the RTA-50D
VDR must be wiped off with a lint-free cloth.
NOTE:
Any cleaning of equipment interiors must be limited to that required when
performing overhaul (bench-type) work.
10. Diagrams (TASK 23-20-59-000-809-A01)
A.
RTA-50D VDR Diagrams (Subtask 23-20-59-000-018-A01)
(1)
Diagrams for the RTA-50D VDR are listed in Figure 2001.
EFFECTIVITY