Section 3: Wireless Devices
3.1 Description
The SWIFT Network consists of the following devices:
FWD-200P - Wireless Photoelectric Smoke Detector -FCC ID: AUBWFSSD
The wireless photoelectric smoke detector is powered by four CR123A batteries. It has a sensor
head to detect smoke and LEDs to indicate the activation and trouble status.
head to detect smoke and LEDs to indicate the activation and trouble status.
FWD-200ACCLIMATE - Wireless Acclimate Detector FCC ID: AUBWFSSD
The wireless Acclimate detector is powered by four CR123A batteries. It has a sensor head to
detect smoke and LEDs to indicate activation and trouble status.
detect smoke and LEDs to indicate activation and trouble status.
FWH-200ROR135 - Wireless Rate of Rise Heat Detector FCC ID: AUBWFSSD
The rate of rise heat detectors are powered by four CR123A batteries. The detectors have LEDs to
indicate the activation and trouble status.
indicate the activation and trouble status.
FWH-200FIX135 - Wireless 135° Fixed Heat Detector FCC ID: AUBWFSSD
The fixed heat detectors are powered by four CR123A batteries. The detectors have LEDs to indi-
cate the activation and trouble status.
cate the activation and trouble status.
FW-MM - Wireless Addressable Monitor Module FCC ID: AUBWFSMM
The wireless monitor module is powered by four CR123A batteries. It can be connected to a switch
within three feet of its location or wired directly to the pull station. The module has LEDs to indi-
cate the activation and trouble status.
within three feet of its location or wired directly to the pull station. The module has LEDs to indi-
cate the activation and trouble status.
FW-RM - Wireless Addressable Relay Module FCC ID:
The wireless relay module is powered by four CR123A batteries
.
It provides the system with a dry-
contact output for activating a variety of auxiliary devices, such as fans, dampers, control equip-
ment, etc. Addressability allows the dry contact to be activated, either manually or through panel
programming, on a select basis. The module has an LED to indicate the activation and trouble sta-
tus.
ment, etc. Addressability allows the dry contact to be activated, either manually or through panel
programming, on a select basis. The module has an LED to indicate the activation and trouble sta-
tus.
For more information on the LED indicators, refer to Section 3.6.2.
3.2 Agency Approvals
3.2.1 FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two con-
ditions:
ditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
2. This device must accept any interference received, including interference that may cause
undesired operation.
!
WARNING: DO NOT MAKE CHANGES TO THE EQUIPMENT.
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE MANUFACTURER
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE MANUFACTURER
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.