ICOM 375410 Manuale Utente

Pagina di 68
35
6
SCANNING
201802
BASIC MANUAL
 
D
Storing Skip frequencies
You can skip unnecessary frequencies during a scan.
While a scan is paused and if you want to skip the 
frequency, you can store it into the Skip channel group S 
(00 ~ 99) as a Skip channel (PSKIP). 
The Scan Skip function speeds up a scan.
1.  Start a VFO scan.
 •When a signal is received, the scan pauses.
2.  Hold down [SKIP] until two short beeps sound.
 •The frequency is stored into the Skip channels group.
 •The entered Memory channel number blinks.
 •After storing, the scan resumes.
 
L
If there is no blank channel, an error beep sounds, 
and the frequency is not stored.
 
D
Program Skip Scan function
This function enables the receiver to skip the unwanted 
frequencies that are entered as Memory channels and are 
set to “PSKIP.” 
(p. 37)
[MENU] > Scan > 
Program Skip
1.  Push [MENU].
2.  Select “Program Skip” in the “Scan” menu.
    (Rotate [DIAL] to select it, and then push [ENTER].)
3.  Select the Program Skip function, “ON” or “OFF,” and 
then push [ENTER].
 •When “ON” is selected,“PSKIP” is displayed above the 
Memory channel number.
 
L
Push [CLEAR] to return to the Main screen.
 
D
Temporary Skip function
This function temporarily skips unwanted frequencies (or 
memory channels) during a scan for the set period of time, 
without changing the Skip Channel setting.
 
L
You can change 
Temporary Skip Timer on the MENU 
screen. (Default: 5 min)
  ([MENU] > Scan > 
Temporary Skip Timer)
1.  Start a scan.
 •When a signal is received, the scan pauses.
2.  After pushing [QUICK], select “Temporary Skip” and 
then push [ENTER].
 •The scan automatically resumes.
 
L
After the Temporary Skip Timer period ends, the 
scan is canceled or the receiver is turned OFF, the 
Temporary Skip function is turned OFF.
[SKIP]
ON
OFF
TIP: 
 •Up to 5 Temporary Skip frequencies or Memory channels can be set. When the 6th 
frequency or Memory channel is set, the oldest setting is automatically deleted.