Installation of the ME401-9 in vehicles 
 
The standard installation for vehicles, where the unit should register operating hours the 
following connections are used: 
 
 
Max. Load 200 mA  
Do NOT use this output to switch off vehicles and machines during operation or driving  
If Main Switch disconnects negative wire (chassis/GND) from battery, it might cause false input activity.  
To avoid that, Pink wire should be connected to the chassis/GND, Blue Wire should be connected to battery 
minus pole and input filtering must be activated
 
 
NOTE:
 
It is recommended always to connect digital input 2 to the ignition signal of the 
vehicle as this is necessary for km recording. 
 
Examples of input/output  or interfaces 
The ME401-9 can be installed with various optional interfaces added to the Input/output 
ports or the device: 
 
•  A one wire ibutton reader. 
 
 
 
 
•  A start relay blocking function for unauthorized access. 
•  Alarms. 
•  etc. 
Wire color 
Connection 
Description 
Red 
 
Power 
Connect to permanent 12 to 48 V supply  
through a 1A fuse 
White 
 
Digital input 1 
Connect to the operating hours counter 
 
Mandatory for machines!  
Brown 
 
Digital input 2 
Connect to the ignition signal
 
Mandatory for vehicles and machines! 
 
Grey 
 
Digital input 3 
Can be connected to an external sensor for detecting a 
critical running mode or an alarm 
Pink 
 
Digital input 4 
Can be connected to an external sensor for detecting a 
critical running mode or an alarm 
3  
Green 
 
1-wire input 
Can be connected to iButton reader or temperature 
sensor  
Yellow 
 
Digital output 1 
Can be used to control external equipment through a 
relay 
1 2  
Blue 
 
Ground