Installation of the ME401-9 in machinery 
 
In this section possible installation proposals are given. The installation proposals are 
listed as examples and can be used as a guide for inspiration for an actual installation.  
 
Standard installation of ME401-9 for registering operating hours: 
For a standard installation in machines where the unit should register the number of 
operating hours etc. use the connections as described in the vehicle installation section. 
 
 
Installing the ME401-9 as to surpass the main switch on the machine: 
 
In case the main switch on the machine will break the negative wire (Ground wire), the 
inputs may register a voltage level and start counting operating hours. To avoid this 
situation the digital input 4 (Pink wire) should be connected to the chassis/ground on the 
machine. Then send the following SMS to the unit (phone number) to activate the filtering:  
 
Function 
Send SMS 
Return-SMS from the unit 
Activate filter function on inputs. 
MT INFILT ON 
MTC ACK (SERIAL No.) INFILT ON
 
 
NOTE: 
Enabling the filtering function will disable the use of the alarm function on digital 
input 4 as listed in the standard installation proposal above. 
 
NOTE: 
It is recommended always to connect digital input 2 to the ignition signal of the 
machine as this is necessary for km recording. 
 
NOTE: 
For the “Send SMS” it is of no importance if small or capital letters are used in 
the command string, or a mixture hereof.