Power supply  
The unit 
must be connected to a +12 to +48 V battery voltage through a 1 amp. fuse. The 
use of a fused supply wire is important for not damaging the wires related to the unit in 
case of a short circuit etc. 
Digital inputs  
The voltage required for activating of a digital input is dependent on the configuration of 
the input ports.  
Digital output 
The digital output has the type indication ”LO-side switch”, that connects the output to 0V 
“ground”, when the output is active. This output can be used to control a relay powered 
from an external DC supply voltage. The maximum current drawn from the output is 
200mA and the voltage from the external supply voltage must not exceed 60 V DC. 
 
The output is protected against short circuits, overload and is also protected against over 
voltage. For further information about connection possibilities of the digital output, see 
chapters about installation later in this manual.  
Motion/acceleration sensor 
The unit has a built-in 3 axis acceleration sensor that is able to activate the unit if it, as a 
consequence of disconnected supply voltage, is in stand-by mode. When motion is 
detected it will also cause activity on ‘Input 7’ on the ME401-9 microcontroller portal. 
1-Wire input 
•  The 1-wire input can be used to read Dallas iButton for access control. The 1-wire 
input is only operational when supply voltage (12 to 48 V) is present. It cannot 
operate on internal battery alone.