Installation of the digital output 
 
According to the E1 certificate of the ME401-9 unit, it is prohibited under any 
circumstances to use this output to control any equipment that may influence the safety of 
the construction machinery and earth moving machines/vehicle operation and driving. The 
output must only be used to control comfort equipment. 
 
The example below shows a relay function. Please ensure that the voltage specification of 
the relay matches the supply voltage. The current consumption of the relay must not 
exceed 200 mA (DC current) and the relay contacts must be specified to withstand the 
load that needs to be controlled. 
 
NOTE: 
The output can only handle DC and 
not AC voltage. It is necessary to only use a 
DC power supply for the relay. 
 
 
 
Important!
  
The power supply connected to the ME401-9 GSM/GPS unit and 
the supply voltage for the relay mounted on the digital output 
must have a common ground connection.  
 
One application example for the “Usable contact function controlled by the ME401-9” 
signals shown in the figure above could be a “Start Relay”, blocking function, for 
preventing unauthorized use of the moving machinery and construction machine or vehicle 
outside normal working hours etc.