Nilfisk-advance Inc. ME401 Manuale Utente

Pagina di 24
 
ME401-9 
 
 
 
 
Nilfisk Advance ME401-9, Technical Manual v1.2, Marts 2014 
 Page 18 
SMS commands for output control 
 
Function 
Send SMS 
Return SMS 
Description 
 
Time controlled 
activation of the 
output 
 
 
MT OUT1=1,30 
 
MTC ACK (SERIAL No.) 
OUT1 TIMER=1 
MINUTES 30 
SECONDS 
 
With this command the output will be 
activated for a number of defined minutes. In 
the example 1 minute and 30 seconds was 
used. The output is activated immediately 
after the acknowledge SMS has been send 
out and it is deactivated automatically when 
the timer runs out. 
NOTE: 
It is possible to break the output before 
the timer runs out by using the “OFF” 
command. 
 
Permanent 
activation of the 
output 
 
MT OUT1=ON 
 
MTC ACK (SERIAL No.) 
OUT1 ON 
 
With this command the output is activated 
permanently. The output can be de-activated 
again using the “OFF” command. 
 
Deactivation of 
the output  
 
MT OUT1=OFF 
 
MTC ACK (SERIAL No.) 
OUT1 OFF 
 
With this command the output is deactivated. 
The command will work for any activation 
mode either “time controlled” or “permanent”. 
 
Warning: Do not use the above mentioned SMS commands for output control if the 
ME401-9 is used for immobilizer purpose, as this will interfere with the 
immobilizer functionality. 
 
NOTE:
 
For the “Send SMS” it is of no importance if small or capital letters are used in 
the command string, or a mixture hereof. 
 
 
Safety precautions 
 
The use of the digital output is restricted to signals/systems/components related 
to comfort applications in the vehicles. 
 
Under no circumstances must it be used for purposes, which can influence the 
safety of the vehicle when driving. 
 
Nilfisk holds no liability for any damages occurred to persons, vehicles, moving 
machines, construction machines etc. caused by wrong installation and/or faulty 
use of the digital output.