Samsung MZMPC128HBFU-00000 Manuale Utente

Pagina di 37
- 31 -
        datasheet
SSD
  Rev. 1.0
MZMPC032HBCD-00000
MZMPC064HBDR-00000
MZMPC128HBFU-00000
MZMPC256HBGJ-00000
7.3.8 Error reporting
The following table shows the values returned in the Status and Error Registers when specific error conditions are encountered by a device.
[Table 7-9] SMART Error Codes
8.0  OOB signaling and Phy Power State
8.1 OOB signaling
8.1.1 OOB signal spacing
There shall be three Out Of Band (OOB) signals used/detected by the Phy: COMRESET,COMINIT, and COMWAKE.  Each burst is followed by idle peri-
ods (at common-mode levels), having durations as depicted in following Figure  and Table.  The COMWAKE OOB signaling is used to bring the Phy out 
of a power-down state (Partial or Slumber)
Error condition
Status Register
Error Register
A S.M.A.R.T. FUNCTION SET command was received by the device without the required key being 
loaded into the LBA High and LBA Mid registers.
51h
04h
A S.M.A.R.T. FUNCTION SET command was received by the device with a subcommand value in the 
Features Register that is either invalid or not supported by this
device.
51h
04h
A S.M.A.R.T. FUNCTION SET command subcommand other than S.M.A.R.T. ENABLE OPERATIONS 
was received by the device while the device was in a "S.M.A.R.T. Disabled" state.
51h
04h
The device is unable to read its Attribute Values or Attribute Thresholds data structure
51h
10h or 04h
The device is unable to write to its Attribute Values data structure.
51h
10h or 40h
Time
Value
T1
106.7 ns
T2
320 ns