Lecroy WAVEACE 1012 2-channel oscilloscope, Digital Storage oscilloscope, WaveAce 1012 Manuale Utente

Codici prodotto
WaveAce 1012
Pagina di 123
Operator's Manual 
98 
WA1K2K-OM-E RevB 
2.  Press the Interval option button and use the Adjust Front Panel 
(on page 10) knob to dial in the desired interval between record 
frames. 
3.  Press the End Frame option button and use the Adjust front panel 
knob to dial in the desired number of record frames. 
4.  Press the Operate option button to Start/Stop recording. 
Note
: A 
record: 1
 counter is shown on the upper-left part of the grid 
display area which counts the number of record frames to your set 
End 
Frame
 amount. After pressing the Operate option button, once the 
End Frame amount is reached, a 
Record Wave Success
 notification is 
then briefly shown on the lower-center part of the grid display area. 
The Record Menu (with Mode Set to Play Back) - Page 1/2 
Press the Mode option button and select Play Back. The Record menu 
(with Mode set to Play Back) - Page 1/2 is shown and contains the 
following option button controls (in addition to Mode). 
 
1.  Press the Operate option button to Start/Stop playback. 
Note
: A 
play: 1
 counter is shown on the upper-left part of the grid 
display area which counts the number of record frames to your 
recorded 
End Frame
 option button control (set on PlayBack Page 2/2) 
amount. If your play mode is set to Circular (repeat) the counter 
continually cycles. Otherwise, if using the Single Time play mode, the 
counter reaches the end frame amount and stops.