Testboy TV 455VDE-tester Testboy TV 455 Manuale Utente

Codici prodotto
Testboy TV 455
Pagina di 76
TESTBOY TV 450 
Technical specification 
 
66 
9.6  Resistance to earth (model TESTBOY TV 450 (TYPE B)) 
 
Measuring range according to EN61557-5 is 2.00 
Ω ÷ 1999 Ω. 
Measuring range (
Ω) Resolution 
(
Ω
Accuracy 
0.00 
÷ 19.99 
0.01 
20.0 
÷ 199.9 
0.1 
200 
÷ 9999 
±(5% of reading + 5 digits) 
 
Max. auxiliary earth electrode resistance R
C
... 100
×R
E
 or 50 k
Ω (whichever is lower) 
Max. probe resistance R
P
................................ 100
×R
E
 or 50 k
Ω (whichever is lower) 
 
Additional probe resistance error at R
Cmax
 or R
Pmax.
 
±(10 % of reading + 10 digits) 
 
Additional error  
at 3 V voltage noise (50 Hz) ............................
±(5 % of reading + 10 digits) 
 
Open circuit voltage ......................................... < 15 VAC 
Short circuit voltage ......................................... < 30 mA 
Test voltage frequency .................................... 125 Hz 
Test voltage shape .......................................... rectangular 
Noise voltage indication threshold ................... 1 V (< 50 
Ω, worst case) 
 
Automatic measurement of auxiliary electrode resistance and probe resistance. 
Automatic measurement of voltage noise. 
 
9.7  Voltage, frequency, and phase rotation 
 
9.7.1 Phase rotation 
 
Nominal system voltage range ......... 100 V
AC
 
÷ 550 V
AC
 
Nominal frequency range.................. 14 Hz 
÷ 500 Hz 
Result displayed ............................... 1.2.3 or 3.2.1 
 
9.7.2 Voltage 
 
Measuring range (V) 
Resolution (V) 
Accuracy 
÷ 550 
±(2 % of reading + 2 digits) 
 
Result type........................................ True r.m.s. (trms) 
Nominal frequency range.................. 0 Hz, 14 Hz 
÷ 500 Hz 
 
9.7.3 Frequency 
 
Measuring range (Hz) 
Resolution (Hz) 
Accuracy 
0.00 
÷ 9.99 
0.01 
10.0 
÷ 499.9 
0.1 
±(0.2 % of reading + 1 digit) 
 
Nominal voltage range...................... 10 V 
÷ 550 V