Technical Data
Mai 06
75
12 Technical Data
12.1 General
GPRS Data transmission
GPRS Multislot class 12
Coding scheme 1 to 4
Coding scheme 1 to 4
Mobile Station
Class B
Support PBCCH
CSD Data transmission
CSD Data transmission
V.21 (300 bps), V.22 (1200 bps), V.22bis (2.400 bps), V.32
(4.800/9.600 bps), V.34 (14400 bps), V.110
(300/1.200/2.400/4.800/9.600/14.400)
(4.800/9.600 bps), V.34 (14400 bps), V.110
(300/1.200/2.400/4.800/9.600/14.400)
Fax
Group 3, class 1
SMS
MO and MT text und PDU mode, and automatic MT SMS
processing
processing
Baud rates
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400, 460800 – for “TCP transparent” connections
only baud rates starting at 9600
115200, 230400, 460800 – for “TCP transparent” connections
only baud rates starting at 9600
Data formats
8N1, 8E1, 8O1, 8N2, 7E1, 7O1, 7N2, 7E2, 7O2
I/O
2 digital inputs (Pull-up), 2 digital outputs
Output power
EGSM 850 and 900: Class 4 (2 W)
GSM 1800 and 1900:
GSM 1800 and 1900:
Class 1 (1 W)
12.2 Physical Features
INSYS GPRS 5.0 serial
Weight
250 g
Dimensions w x l x h
55 x 110 x 75
Temperature range
32 °F - 131 °F
Protective class
Housing IP 40/screw termination IP 20
Humidity
0 – 95% non-condensing
12.3 Power Supply
All specified technical data was measured with a nominal input voltage, full load, and an
ambient temperature of 77.00 °F. The threshold value tolerances are subject to the typi-
cal fluctuations. A maximum of one value may be operated in the threshold value range.
The values were determined for a GSM receiving field strength of 16. For lower field
strengths on site the values will increase, especially for CSD or GPRS data transmissions.
The current consumption during data transmissions may also increase if the antenna is
not adjusted correctly.
This can occur for the following cases:
The antenna and/or the antenna cable are not adjusted to 50 Ω impedance.
ambient temperature of 77.00 °F. The threshold value tolerances are subject to the typi-
cal fluctuations. A maximum of one value may be operated in the threshold value range.
The values were determined for a GSM receiving field strength of 16. For lower field
strengths on site the values will increase, especially for CSD or GPRS data transmissions.
The current consumption during data transmissions may also increase if the antenna is
not adjusted correctly.
This can occur for the following cases:
The antenna and/or the antenna cable are not adjusted to 50 Ω impedance.