Insys GPRS 5.0 serial 11-02-01-03-10.014 Manuale Utente

Codici prodotto
11-02-01-03-10.014
Pagina di 82
INSYS GPRS 5.0 serial 
 
Technical Data 
 
Mai 06 
            75 
12 Technical Data 
12.1  General 
GPRS Data transmission 
GPRS Multislot class 12 
Coding scheme 1 to 4 
Mobile Station 
Class B 
Support PBCCH 
CSD Data transmission 
V.21 (300 bps), V.22 (1200 bps), V.22bis (2.400 bps), V.32 
(4.800/9.600 bps), V.34 (14400 bps), V.110 
(300/1.200/2.400/4.800/9.600/14.400) 
Fax 
Group 3, class 1 
SMS 
MO and MT text und PDU mode, and automatic MT SMS 
processing 
Baud rates 
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 
115200, 230400, 460800 – for “TCP transparent” connections 
only baud rates starting at 9600 
Data formats 
8N1, 8E1, 8O1, 8N2, 7E1, 7O1, 7N2, 7E2, 7O2 
I/O 
2 digital inputs (Pull-up), 2 digital outputs 
Output power 
EGSM 850 and 900:  Class 4 (2 W) 
GSM 1800 and 1900: 
Class 1 (1 W) 
 
12.2  Physical Features 
 
INSYS GPRS 5.0 serial 
Weight  
250 g 
Dimensions w x l x h 
55 x 110 x 75 
Temperature range 
32 °F - 131 °F 
Protective class 
Housing IP 40/screw termination IP 20 
Humidity 
0 – 95% non-condensing 
12.3  Power Supply 
All specified technical data was measured with a nominal input voltage, full load, and an 
ambient temperature of 77.00 °F. The threshold value tolerances are subject to the typi-
cal fluctuations. A maximum of one value may be operated in the threshold value range. 
The values were determined for a GSM receiving field strength of 16. For lower field 
strengths on site the values will increase, especially for CSD or GPRS data transmissions. 
The current consumption during data transmissions may also increase if the antenna is 
not adjusted correctly.  
This can occur for the following cases: 
The antenna and/or the antenna cable are not adjusted to 50 Ω impedance.