Insys ISDN Terminal Adapter 4.0 11-02-01-02-00.015 Manuale Utente

Codici prodotto
11-02-01-02-00.015
Pagina di 60
Configuration 
15 
Version 2.02 – 01.04 
 
 
5.1.3  Configuration With X3.PAD 
To execute a TA+ configuration command out of the X.3 - PAD command mode you have 
to enter the command exec cmd
Use the command conf to start the TA+ configurator. 
You can leave the TA+ configuration program with the command quit
Note: 
After changing a value marked with (#1), you have to enter the commands  
save
  and  go  additionally. This is necessary to save and activate the new pa-
rameter. 
5.1.3.1  X.3 Command Set 
If you connect a serial interface to the X.31 service, you can use the integrated PAD of the 
INSYS ISDN TA. You can use for example the command stat to display the status of the 
connection. 
Use the configuration command cmds = 1 to set the PAD mode. 
The following PAD-Commands according to X.28/X.29 are supported: 
•    (dot) 
Displays PAD identification 
 
[Pxxx-][R ][N<nuipwd> ][G<cug> ]X25number[I<ISDNnumber>][D<userdata>] 
Establishes an X.25 connection 
 use 
packet 
size 
xxx
 for X.25 connection 
 
request the facility reverse charging (only for X.25) 
 
access to a closed X.25 user group   
 
outgoing call from a closed X.25 user group 
use NUI and password in call packet, allowed characters:
  a-z, A-Z, 0-9. (overrides setting of nui configuration com-
mand) 
X25number   dialed X.25 call number 
ISDNnumber   ISDN call number for a dialed B channel connection 
 
separator for user data: DP or , 
clr 
terminate an X.25 connection 
stat 
displays the PAD connection status 
set 
sets the PAD profile to profile 0 
set x:n 
sets the PAD profile parameter x to value n 
prof x 
configures to the PAD profile xx = 0..7, 90, 91 
prof? 
displays the configured PAD profile parameters 
par [x][,x]  displays all configured PAD profile parameters or the PAD parameter x par 
without parameter displays all settings