Insys Modem 56k 4.1 m/UL 11-02-01-01-40.022 Manuale Utente
Codici prodotto
11-02-01-01-40.022
Configuration
INSYS Modem 56k UL
16 Juni
05
4.6.3 AT Commands For Alarm Actions
Command Description
AT%A alarm
triggering
AT*I
manual request of the alarm input
AT*M
protocol for alarm messages
AT*V alarm
text
AT&Z
store telephone numbers (mobile, service center, fax)
ATS13
number of dialing attempts
A comprehensive description of all AT commands and parameters is available in the ad-
dendum „command overview“.
dendum „command overview“.
4.7 Command Input Mode
At power up INSYS Modem is in the command input mode ready to receive AT commands
from the serial line. When a data connection is established the modem can be set back to
command input mode by the following escape sequence:
from the serial line. When a data connection is established the modem can be set back to
command input mode by the following escape sequence:
1 second break (no input)
3 plus characters (+++) without Return
1 second break (no input)
3 plus characters (+++) without Return
1 second break (no input)
Data connection is held in the background.
AT Commands For Command Input Mode
Command Description
ATO
switch to online data mode
<break> +++ <break> switch to command input mode
A comprehensive description of all AT commands and parameters is available in the ad-
dendum „command overview“.