Secutech Radio modules ST002010 Scheda Tecnica

Codici prodotto
ST002010
Pagina di 16
Security & Electronic Technologies GmbH
  
Page 7
 
 
 
 
 
 
If no data are coming in from the host device A SECU-DATA 1232 will wait 
for the time defined herewith and afterwards it will send the data from the 
RS 232 input buffer via RF: 
 
On  the  other  hand  SECU-DATA  1232  transmits  the  data  independently 
from the time out as soon as the buffer of 64 bytes is full. 
 
After  the  last  input  the  settings  stored  in  the  internal  flash  memory  and 
SECU-DATA 1232 is restarted (RESET). 
Abortion: 
In  case  of  incorrect  inputs  press  the  button  “B”  before  you  have 
entered the last parameter. The new settings are deleted and SECU-DATA 
1232 will be restarted (RESET). 
Selection of RF-frequency Channel Block  
SECU-DATA 1232 uses one RF-channel out of 64, these are organised in 8 
blocks  of  8  channels  each.  After  delivery  frequency  channel  block  6  is  set 
as  default.  Two  SECU-DATA  1232  devices  can  communicate  only  if  the 
same frequency channel block is set on both devices. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RS 232 data from
 Host device
Timeout
RTS of SECU-DATA 232
Data transmission via RF
Button B 
Button A