Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Interfacing with the LS8000-3 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 74 of 221 
Revision A (Sep 2007) 
Index Pulse & Length Thresholds 
The Index Pulse and Length Thresholds can be used to control a cutter and 
provide pre-cut queues to the process control system so, for example, the line 
can be slowed prior to a cut.  The Index Pulse is configured to trigger at a 
specified length interval, and the Length Thresholds can be configured to 
trigger at preset lengths before the Index Pulse triggers.  The Length 
Threshold outputs remain high until the Index Pulse triggers and resets.  The 
index pulse automatically resets the Length Threshold outputs—no external 
wiring is required. 
Another way to reset these outputs is to set the Index Pulse Setting to a high 
value and reset the threshold outputs by asserting the Length Reset Input.  
The Length Thresholds are available as an alternate output function of the 
User Scaleable Pulse Output. 
Example: 
Setting 
Value 
Index Pulse Setting 
100 m 
Index Pulse Length 
100 ms 
Length Threshold A 
90 m 
Length Threshold B 
80 m