Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Interfacing with the LS8000-3 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 75 of 221 
Revision A (Sep 2007) 
 
Gauge-Gauge Synchronization 
LaserSpeed LS9000 and LS8000 gauges can be synchronized so that their 
sampling periods are synchronized, and so they update their outputs at the 
same time. 
The simplest method for synchronizing gauges is to connect each gauge to a 
LaserSpeed I/O module and connect the I/O Modules' synchronization 
connects together.  The I/O Modules will automatically synchronize the gauges 
and calculate elongation, which can be output in a variety of different ways. 
Another method for synchronization is to reconfigure the gauges' High Speed 
Pulse Output ports and connect the gauges together in a daisy-chain 
configuration.  The gauges will synchronize to each other, but will not calculate 
elongation.  If an elongation calculation is required, the RS232, RS422, or 
Ethernet output data from each gauge must be collected and calculated in an 
external PLC or computer. 
To configure the High Speed Pulse Output to output the synchronization 
signal, use LaserTrak to set the High Speed Pulse Config option "A=Pulse 
Phase A, B=Sync Out"
.  This will replace the pulse output phase B with the 
synchronization output, and will leave Phase A available for connection to a 
counter.