Eclipse Combustion EGA4 Manuale Utente

Pagina di 50
 
 
 
Instruction Manual MM850481 ed.01 
2 GENERAL 
2.1 
Keypad & Display  
The tactile keyboard allows the operator to enter the main operative mode and all other complementary or auxiliary 
modes following the menu driven instructions. 
The high contrast graphic LCD (40x56 mm), equipped with an automatic back-light device, displays the measured and/or 
calculated parameters in the preferred format (Zoom function). The above parameters can be also displayed in a graphic 
mode. 
2.2 Built-in 
printer 
EGA4 can be equipped with a built-in, rugged, impact type printer. It uses a low cost common roll of paper (58 mm large, 
18 meters long) , more readable, long time and heat resistant better than the thermal printout on chemical paper. One 
key instruction is enough to obtain one, two or more copies of the analysis report with header and company reference 
data. 
2.3 
Gas sampling probe 
Flue gas sampling probes with different length, shape and max. operating are available to match the requirement of 
different applications. The sampling probe is connected to the instrument with a rubber hose through a combined module 
of water trap and suspended particle filter. 
2.4 Measuring 
cells 
EGA4  uses long life sensors for O
2
, CO (H
2
 compensated), NO, NO
2
 and SO
2
. An automatic device exclude 
automatically the CO sensor when CO high concentration level is identified. 
Four acoustic and visual alarms can be set on four programmable parameters. 
2.5 Temperature 
probes 
A thermocouple type K is incorporated on the tip of the gas sampling probe to measure the flue gas temperature. This 
thermocouple is suitable for measurements up to 800°C (max 1000°C for few seconds). Temperature measurement and 
gas sampling from the flue gas pipe are thus always performed in the same site. 
The probe is connected to the instrument with the appropriate compensated cable and connector. A Pt100 resistance 
thermometer (local jig or remote sensor) is used  for the air temperature measurement and best efficiency calculation. 
2.6 Pressure 
sensor 
The instrument is equipped with an internal sensor for pressure and stack draught. One key instruction move the 
operative mode to and from this function to gas analysis and viceversa. The instrument has, as standard feature, a 
differential pressure sensor. 
2.7 
Fuel technical data  
The instrument includes as standard the technical data for 4 of the most common fuels. 
Using the optional GasConfig software, it is possible to modify or add data of up to 10 different fuels.