2.1 L Hydraulic Pump Installation Instructions
Pump Valves and Fittings
The 2.1 L pump can be connected to the hydraulic system using one of two methods. The five-connector method (
) uses the C1
➊
and
C2
➋
fittings to connect the pump to the cylinder and the H1
➌
and H2
➍
fittings to connect the pump to the helm. The three-connector method
uses only the H1 and H2 fittings, with a t-connector splitting the connection between the helm and cylinder. The return line fitting
➎
is
used in both cases to connect to only the helm. The check valves
➏
do not need to be reconfigured if the boat is equipped with a balanced cylinder.
If the boat is equipped with an unbalanced cylinder, the check valves must be reconfigured (
). The bypass valve
➐
is only opened for
hydraulic bleeding, and must be fully tightened during normal operation.
➌
➊
➋
➍
➎
➐
➏