NOTE
It is recommended the access point be mounted with the RJ45 cable connector oriented upwards 
or downwards to ensure proper operation.
11
Cable the access point using either the Power Injector solution or the power supply.
For Power Injector installations:
a
Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data 
supply (host) and the Power Injector Data In connector.
b
Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector 
Data & Power Out connector and the access point’s GE1/POE port.
c
Ensure the cable length from the Ethernet source to the Power Injector and access 
point does not exceed 100 meters (333 ft). The Power Injector has no On/Off 
power switch. The Power Injector receives power as soon as AC power is 
applied. 
For standard 48 volt power adapter (5014000247R) and line cord installations:
a
Connect RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply 
(host) and the access point’s GE1/POE port.
b
Verify the power adapter is correctly rated according the country of operation.
c
Connect the power supply line cord to the power adapter.
d
Attach the power adapter cable into the power connector on the access point.
e
Plug the power adapter into an outlet.
For PoE-enabled switch or controller installations:
a
Connect an RJ-45 CAT5e (or CAT6) Ethernet cable between a PoE-enabled port 
and the access point’s GE1/POE port.
b
Ensure the cable length from the PoE-enabled port to the access point does not 
exceed 100 meters (333 ft). 
c
Verify power is enabled on the PoE-enabled port.
CAUTION
Do not actually apply power to the AP until the cabling portion of the installation is complete.
12
Verify the behavior of the access point LEDs. For more information, see