Manuale UtenteSommarioChapter 1. Introduction71.1 Preface71.2 Overview71.3 Function Descriptions81.3.1 Rectifier Control81.3.2 Converter Control81.3.3 System Components Monitoring and System Alarms Generation91.3.4 Operating Data Acquisition and Data Logs91.3.5 Battery Management10General Battery Management10Spec. No. 588820300 Battery Rack System (Lithium Ion Battery Configuration)10Battery Charge Temperature Compensation11Battery Equalize Charge and Battery Charge Current Limit12High and Low Battery Temperature Alarms12Battery Thermal Runaway Management (BTRM) Feature12Battery Discharge Test and Battery Test Logs13Battery LVD (Low Voltage Disconnect)14Battery Capacity Prediction14Battery Block and Battery Midpoint Monitoring14Enhanced Battery Monitoring with SM-BRC14Thermal Runaway Detection and Management141.3.6 Intelligent Power Matching (Energy Optimization Mode)141.3.7 Power Split Feature151.3.8 Diesel Management Feature151.3.9 PLC (Programmable Logic Controller) Function161.3.10 Supervisory Module (SM Modules) Monitoring161.3.11 Hybrid Control Function16General16Hybrid Operation17Charge Voltage:17Early Termination of the Discharge Periods19Operation with Grid Power19Relay Assignment – when in Hybrid Mode19Fixed Daily20Capacity Discharge201.3.12 Maximum Current Limit Function21Chapter 2. Operation222.1 Local Indicators222.2 Passwords and Access Levels232.3 Local Keypad and Display Access242.3.1 Local Menu Navigation Keys and LCD Display242.3.2 Local Display Menus24Navigating the Menus242.4 WEB Interface Access252.4.1 Overview252.4.2 Setting IP Communications Parameters252.4.3 WEB Interface Menus252.4.4 Connecting the Controller Locally (via the Ethernet Port)25Procedure252.4.5 Disabling Proxy Server Settings to Enable a Connection to the Controller over an Intranet Network (if required)26Procedure262.4.6 Logging into the Controller27Procedure272.5 Common Tasks Performed via the Local Keypad and/or Web Interface282.5.1 Backing Up the Configuration282.5.2 Reloading a Backed-Up Configuration282.5.3 Reloading the Configuration File Stored in the ACU+ Controller282.5.4 Downloading a Configuration or an Application ("All") Package into the ACU+ Controller29To Download a Configuration Locally:29To Download an Application ("All") Package Locally:292.5.5 Rebooting the Controller302.5.6 Changing the Local LCD Display Contrast302.5.7 Disabling the Local Keypad Sound302.5.8 Changing the Date302.5.9 Changing the Time302.5.10 Adding, Deleting, and Modifying Users302.5.11 Assigning Severity Level to Alarms302.5.12 Assigning Relays to Alarms312.5.13 Changing the Names of Items Displayed in the LCD and Web-Interface Menus312.5.14 Viewing Alarms312.5.15 Clearing Rectifier Lost, Rectifier Communication Fail, Converter Lost, Converter Communication Fail, and All Converter Comm Fail Alarms312.5.16 Clearing SMTemp Lost and SMTemp Probe Alarms312.5.17 Clearing Battery Alarms312.5.18 Clearing Logs312.5.19 Clearing the Maintenance Alarm322.5.20 Viewing the ACU+ Controller’s Device Inventory322.5.21 Updating the ACU+ Controller’s Device Inventory322.5.22 Programming the Audible Alarm Feature322.5.23 Blocking Alarms322.5.24 Configuring the ACU+ Identification of Rectifiers and Assigning which Input Phase is Connected to the Rectifiers33Local Procedure332.5.25 Configuring the ACU+ Identification of Converters34Local Procedure342.5.26 Viewing/Changing the Float Voltage Setting352.5.27 Viewing/Changing the Equalize Voltage Setting352.5.28 Setting Digital Inputs352.5.29 Setting Temperature Sensors352.5.30 Setting Battery Charge Temperature Compensation362.5.31 Setting Auto Equalize362.5.32 Setting Battery Parameters372.5.33 Setting Battery Capacity Parameters372.5.34 Setting Battery Block and Battery Midpoint Monitoring (if equipped with an EIB Assembly)372.5.35 Setting IP Communications Parameters372.5.36 Setting External Shunts (connected to the EIB Assembly)372.5.37 Setting External Shunts (connected to the SM-DU+ Assembly)372.5.38 Setting the Load Current Alarm382.5.39 Placing the System in Float or Equalize Charge Mode382.5.40 Manually Forcing Relays382.5.41 Manually Forcing LVDs382.5.42 Using the Relay Test Feature39Automatic Test39Individual Test392.5.43 Spec. No. 588820300 Battery Rack System (Lithium Ion Battery Configuration)402.6 Available Alarms412.7 Power Split Feature792.7.1 Overview792.7.2 How Power Split Works79Low Load Operation79Normal Load Operation79High Load Operation79Over Load Operation802.7.3 Operating Modes802.7.4 Requirements and Conditions802.7.5 Paralleling the Existing and ACU+ Power Systems81Admonishments81General Safety81AC Input Voltages81DC Input/Output Voltages81Preparing the Existing and ACU+ Power Systems81Paralleling the Systems812.7.6 Programming the ACU+ Power Split Feature83Procedure83Optional Function Setup83Equalize Charge Setup83Battery Test Setup83Low Voltage Disconnect Setup84Temperature Compensated Battery Charge842.7.7 Verifying the Operation of the Power Split Feature85Chapter 3. Local Display Menus863.1 Overview863.2 Menus863.2.1 Adjustment Range Restrictions87Float Voltage Setting87EQ Voltage Setting87HVDS Limit87Under Voltage 1 Alarm Setting87Under Voltage 2 Alarm Setting87Over Voltage 1 Alarm Setting87Over Voltage 2 Alarm Setting87LVD1 and LVD2 Disconnect Setting87LVD1 and LVD2 Reconnect Setting873.3 Description of Local Display (and Web Interface) Menus Line Items983.3.1 Settings Menu98Alarm Setting98Alarm Severity Menu98Alarm Relay Menu98Alarm Param Menu98Power System99General Menu99Power Split Menu101Rectifier101All Rect Set Menu101Rect #1 Menu102Battery103Basic Menu103Charge Menu103Test Menu104Temp Comp Menu105Capacity Menu106Battery # Menu106BattFuseUnit106BattFuseUnit Menu106DC106DC Menu106LVD107LVD Group Menu107LVD Unit Menu107SMDU 1 LVD Menu108AC108Rect AC Menu108EIB109EIB 1 Menu109SMDU110SMDU 1 Menu110Converter110All Conv Set Menu110Conv #1 Menu110SMTemp111SMTemp # Menu111Communication111Communication Menu111Controller111Controller Menu1113.3.2 ECO Mode (Energy Optimization) Menu1123.3.3 Manual Menu112Man/Auto Set112Man/Auto Set Menu112Power System112Power System Menu112Rectifier113All Rect Ctrl Menu113Rect #1 Menu113Batt Group113Batt Group Menu113LVD114LVD Unit Menu114EIB114EIB 1 Menu114Converter114All Conv Ctrl Menu114Conv #1 Menu115SMTemp115SMTemp Group Menu115SMTemp # Menu1153.3.4 Quick Setting Menu115Auto/Manual115Auto/Manual Menu115ECO Mode Set116ECO Mode Set Menu116FLT/EQ Volts116FLT/EQ Volts Menu116FLT/EQ Set116FLT/EQ Set Menu116Temp Comp117Temp Comp Menu117Rectifier Expansion118Rectifier Expansion Menu118Chapter 4. WEB Interface Menus1194.1 Overview1194.2 Homepage119System Status Area119Load Trend Area119Menu Navigation Area119Alarms Area120Temperature Readings1204.3 Menu Navigation Window1214.3.1 Alarms1224.4 Device Information Menu1244.4.1 Rectifier Group124Status Tab124Control Tab125Selecting an Individual Rectifier from the Rectifier Group1274.4.2 Battery Group (except Li-Ion Battery Configuration)129Status Tab129Control Tab130Settings Tab131Selecting an Individual Battery String from the Battery Group1324.4.3 Battery Group (Li-Ion Battery Configuration)134Status Tab134Control Tab134Settings Tab135Individual Battery1354.5 Quick Settings Menu1364.6 Query Menu1374.6.1 Alarm History Log Sub-Menu1374.6.2 Data History Log Sub-Menu1384.6.3 Control/System/Diesel Log Sub-Menu1394.6.4 Battery Test Log Sub-Menu1404.7 Maintenance Menu1414.7.1 Network Configuration Sub-Menu1414.7.2 NMS (Network Management System) Configuration Sub-Menu1424.7.3 HLMS (High Level Management System) Configuration Sub-Menu1434.7.4 Edit PowerSplit Sub-Menu1444.7.5 User Information Settings Sub-Menu145Adding a User145Modifying an Existing User146Deleting a User146User Authority Level1464.7.6 Clear Data Sub-Menu1474.7.7 Restore Factory Defaults Sub-Menu1484.7.8 Download Sub-Menu1494.7.9 Retrieve ‘SettingParam.run’ File Sub-Menu1514.7.10 Time Sync Sub-Menu1524.7.11 System Inventory Sub-Menu1534.8 Configuration Menu1544.8.1 Auto Configuration Sub-Menu1544.8.2 Site Information Modification Sub-Menu1554.8.3 Equipment Information Modification Sub-Menu1564.8.4 Signal Information Modification Sub-Menu157Sample Signal Name Modification Procedure1574.8.5 Alarm Suppressing Sub-Menu1594.8.6 PLC Sub-Menu161Operation161Procedure161Column Descriptions1624.8.7 Alarm Relay Sub-Menu164Chapter 5. Accessing the Controller via a Network Management System (NMS)1655.1 General1655.2 NMS Supported by SNMP Agent1655.3 MIB Installation1655.3.1 Installation1655.3.2 Contents of the Controller’s MIB1655.4 Accessing the Controller through an NMS1695.4.1 Apply Administrative Authority169Add NMS through Web Browser169Chapter 6. Replacement Procedures1706.1 ACU+ Controller Replacement170Procedure170Chapter 7. Specifications172For More Information175Dimensioni: 5,89 MBPagine: 176Language: EnglishApri il manuale