INSTALLATION
Continued
 Tee  Pipe  Cap
 Joint  Nipple
Tee Joint
Reducer 
Bushing to 
1/8" NPT
1/8" NPT 
Plug Tap
*  A CSA design-certified equipment shutoff 
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase 
the optional CSA design-certified equipment 
shutoff  valve  from  your  dealer.  See  Acces-
sories
, page 21.
Figure 15 - Gas Connection
Pressure 
Regulator
T
es
t G
au
ge
 C
on
ne
ct
io
n*
Heater 
Cabinet
Sediment Trap
3" 
Min.
Natural Gas
From Gas 
Meter (7" W.C. 
to 10.5" W.C. 
Pressure)
Propane/LP
From External 
Regulator 
(11" W.C. to 14" 
W.C. Pressure)
Regulator 
Bracket
Ground 
Joint 
Union
3/8" NPT 
Pipe 
Nipple
IMPORTANT:  Install  an  equipment  shutoff 
valve  in  an  accessible  location.  The  equip-
ment shutoff valve is for turning on or shutting 
off the gas to the appliance.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 
going into pipe. Excess sealant in pipe could 
result in clogged heater valves.
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas.
CHECKING GAS CONNECTIONS
 WARNING: Test all gas piping 
and  connections,  internal  and 
external to unit, for leaks after 
installing or servicing. Correct 
all leaks at once.
 WARNING: Never use an open 
flame to check for a leak. Apply a 
noncorrosive leak detection fluid 
to all joints. Bubbles forming show 
a leak. Correct all leaks at once.
  CAUTION:  For  propane/LP 
gas, make sure external regula-
tor has been installed between 
propane/LP supply and heater. 
See guidelines under Connect-
ing to Gas Supply, page 11.
PRESSURE TESTING GAS SUPPLY 
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)
1.  Disconnect  appliance  with  its  appliance 
main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping 
system. Pressures in excess of 1/2 psig 
will damage heater regulator.
2.  Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3.  Pressurize supply piping system by either 
opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas or using compressed air.
Equipment 
Shutoff 
Valve*
Connection Using Flexline
3/8" NPT/ 1/2" 
Flare 90° Elbow
Flexline
See 
illustration 
above for 
detail
Refer to connector's 
instructions
Install sediment trap in supply line as shown 
in Figure 15. Locate sediment trap where it 
is within reach for cleaning. Locate sediment 
trap  where  trapped  matter  is  not  likely  to 
freeze. A  sediment  trap  traps  moisture  and 
contaminants.  This  keeps  them  from  going 
into  heater  controls.  If  sediment  trap  is  not 
installed  or  is  installed  wrong,  heater  may 
not run properly.
IMPORTANT:  Hold  the  pressure  regulator 
with  wrench  when  connecting  it to gas pip-
ing and/or fittings. Do not over tighten pipe 
connection to regulator. The regulator body 
could be damaged.