Desa LCR26PT ユーザーズマニュアル

ページ / 56
www.desatech.com
121255-01A
14
OPERATION
Continued
Figure 20 - Pilot
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do 
not use any phone in your building.
• Immediately  call  your  gas  supplier 
from a neighbor’s phone. Follow the 
gas supplier’s instructions.
• If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn 
the gas control knob. Never use tools. 
If the knob will not push in or turn by 
hand, don’t try to repair it, call a qualified 
service technician. Force or attempted 
repair may result in a fire or explosion.
D.  Do  not  use  this  appliance  if  any  part 
has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.
LIGHTING 
INSTRUCTIONS
1.  STOP! Read the safety information start-
ing on page 13.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Turn off any electric power to the appli-
ance if service is to be performed.
4.  Turn control knob clockwise 
 to the 
OFF position.
5.  Wait  five  minutes  to  clear  out  any  gas. 
Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information starting on page 
13. If you don’t smell gas, go to the next 
step.
6.  Turn control knob counterclockwise 
 
to  the  PILOT  position.  Press  in  control 
knob for five (5) seconds.
7.  With control knob pressed in, push down 
and release ignitor button. This will light 
pilot. The pilot is attached to the front of 
burner.
 
Note: You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, you may need to press in control 
knob  for  30  seconds  or  more.  This  will 
allow air to bleed from the gas system. If 
needed, keep pressing ignitor button until 
pilot lights. If ignitor does not light pilot, re-
fer to Troubleshooting, page 18 or contact 
a qualified service person or gas supplier 
for repairs. Until repairs are made, light 
pilot with match. To light pilot with match, 
see Manual Lighting Procedure, page 15.
8.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
• If  control  knob  does  not  pop  up  when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.
 
Note: If pilot goes out, repeat steps 4 thru 
7. Wait one (1) minute before lighting pilot 
again.
9.  Turn control knob counterclockwise 
 
to desired heating level. The main burner 
should light.
10. To leave pilot lit and shut off burners only, 
turn control knob clockwise 
 to the 
PILOT position.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
Figure 19 - Control Knob In The OFF 
Position
O
FF
    
PIL
OT
 
Control 
Knob
Ignitor 
Button
Thermocouple
Ignitor Electrode
Pilot Burner