Vermont Casting 3225 ユーザーズマニュアル

ページ / 44
20
20
Radiance Direct Vent/Natural Vent Gas Heater 
20004188
Install Log Set
Before beginning log installation, remove stove front 
and glass frame. Refer to Figures 36 and 37.
ST139
Radiance
remove front
4/20/01   djt
ST139
Fig. 36  Remove the stove front.
ST141
pull glass latch
10/99 
ST141
Fig. 37  Release the latches to remvoe the glass frame.
1.  Remove the logs from their packaging, and inspect 
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS. 
The rear log bracket is shipped pack-
aged with the logs.
2.  Install the rear left log by placing it on the sheet 
metal shelf at the back of the firebox. (Fig. 39) The 
log should touch the back wall of the firebox. Slide 
the log to the left until the left side lines up with the 
left  bracket. (Fig. 39) When the log is in place the 
left front corner of the log should rest on the decora-
tive grate.
3.  Install the rear right log by placing it on the sheet 
metal shelf at the back toward the right. Make 
sure the right side of the log lines up with the right 
bracket. (Fig. 39) NOTE: When the right and left rear 
logs are in place, they should touch the back of the 
firebox and each other.
The Radiance stove, when installed as a Natural vent 
heater, includes a vent safety switch. (Page 34, Figure 
67) Operating the stove when it is not connected to a 
properly  installed and maintained venting system, or 
tampering with or disconnecting the vent safety switch, 
can result in carbon monoxide (CO) poisoning and 
possible death.
For U.S. installations: The venting system must 
conform with local codes and/or the current National 
Fuel Gas Code, ANSI Z22.1.
For Canadian installations: The venting system must 
conform to the current CSA B149.1 installation code.
Install the Vent Pipe
Apply a bead of sealant around bottom end of inner 
starter pipe (found in bag with logset) and attach to 
stove. Apply a bead of sealant around top of inner 
starter pipe and install the Z31D00 FSDHAG Draft 
Hood according to Draft Hood instructions. (Fig. 35)
Attach the first section of venting to the draft hood. 
Depending on the length of the individual venting 
sections and the lengths of the decorative pipe (if 
installed), you may need to slip the decorative pipe over 
the venting sections before attaching upper sections 
to lower ones. The sections of decorative pipe should 
be oriented with their seams (if any) toward the wall; 
sections usually do not need to be fastened at each 
joint, other than slip sections. If the layout includes 
a slip section, this should be the last section of pipe 
visible in the room, at the ceiling. Complete the venting 
according to the vent maker’s instructions.
ST357
attach draft hood
4/26/00   djt
���
���
CEMENT
Fig. 35  Install draft hood adpater (FSDHAG).
ST655
Refer to FSDHAG 
instructions for wiring 
on Page 34