Sharp AY-XPC9JR ユーザーズマニュアル

ページ / 116
GB-14
BEFORE CALLING FOR SERVICE
The following conditions do not denote equip-
ment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on immediately 
after it is turned off. The unit will not operate 
immediately after the mode is changed. This is to 
protect the internal mechanisms. Wait 3 minutes 
before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR 
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the unit  
may  be sent out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound 
is generated by the friction of the front panel and 
other components expanding or connecting due to a 
temperature change.
A LOW BUZZING NOISE EMITTED
This is a sound emitted when the unit is generating 
Plasmacluster ions.
SWISHING NOISE
The soft, swishing noise is the sound of the refrigerant 
fl owing inside the unit.
WATER VAPOUR
• In the COOL and DRY operation, water vapour 
can sometimes be seen at the air outlet due to the 
difference between the room air temperature and 
the air discharged by the unit.
• In the HEAT operation, water vapour may fl ow  out 
of the outdoor unit during de-icing. 
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit will rotate 
its' fan for about a minute to cool down the unit.
ODOR EMITTED FROM THE PLASMACLUSTER 
AIR OUTLET
This is the smell of ozone generated from the 
Plasmacluster Ion generator. The ozone concentration 
is very small, posing no adverse effect on your health. 
The ozone discharged into the air rapidly decomposes, 
and its density in the room will not increase.
When using your air conditioner with multi-
system
INDOOR UNIT BECOMES WARM EVEN WHEN 
IDLE
This is because the refrigerant also fl oes through the 
idle indoor unit's pipes when the other unit is operated 
in HEAT mode.
INDOOR UNIT BECOMES WARM EVEN WHEN 
NOT DURING HEATING OPERATION
When the PLASMACLUSTER button is pressed while 
the unit is not operating, the PLASMACLUSTER 
operation will be performed without accompanying 
air conditioning mode (eg. HEATING or COOLING). 
At this time, you may feel warm air coming out from 
the unit air outlet if HEATING is performed with units 
in other rooms. Indoor fan will decrease its rotating 
speed and will turn ON and OFF depending on the 
room temperature.
UNIT DOES NOT OPERATE IN YOUR REQUESTED 
MODE
• When one indoor unit is operating in COOL or 
DRY mode, you can not operate the other unit in 
HEAT mode. (After a few seconds, a long BEEP 
will be emitted, and the temperature indicator 
on the indicator panel will indicate” 
 ” and the 
OPERATION lamp and TIMER lamp will blink 
alternately.)
• When one indoor unit is operating in HEAT mode, 
you can not operate the other unit in COOL nor 
DRY mode. (After a few seconds, a long BEEP 
will be emitted, and the temperature indicator 
on the indicator panel will indicate”   ” and the 
OPERATION lamp and TIMER lamp will blink 
alternately.)
UNIT DOES NOT SEND OUT AIR (PLASMACLUSTER 
operation without accompanying air conditioning 
mode, SELF CLEAN operation)
The other unit(s) is/are de-icing.
If the unit appears to be malfunctioning, check the 
following points before calling for service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the 
fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE 
ROOM EFFECTIVELY
• Check the fi lters. If dirty, clean them.
• Check the outdoor unit to make sure nothing is 
blocking the air inlet or outlet.
•  Check the thermostat is proper setting. 
•  Make sure windows and doors are closed tightly. 
• A large number of people in the room can prevent 
the unit from achieving the desired temperature.
• Check whether any heat-generating appliances are 
operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE 
CONTROL SIGNAL
• Check whether the remote control batteries have 
become old and weak.
•  Try to send the signal again with the remote control 
pointed properly towards the unit’s signal receiver 
window.
• Check whether the remote control batteries are 
installed with the polarities properly aligned.
Please call for service when TEMPERATURE 
INDICATOR on the indicator panel blink.