Friedrich HEAT PUMPS ユーザーズマニュアル

ページ / 28
14
920-087-04
Section III – Chassis Installation
1.  Remove the weatherboard and center support from the sleeve 
(if still in place). Be sure an outdoor grille is attached.
Check to be sure the wall sleeve, extension (if used), grille, and drain kit are installed properly before chassis installation.
2.  Remove the front cover contained in a protective plastic bag 
from chassis. Remove the bag and dispose of it properly.
 
If the control door is not installed, follow these steps:
•  From the front of the cover, slide the right control door pin 
into the hole on the right side of the front cover. Slide the 
left door pin into the hole on the left side of the front cover 
opening and snap it into place.
3.  Remove the two chassis shipping brackets from the ends 
of the shipping pallet.
NOTE:  To avoid breaking the door or hinge pins, do not apply 
excessive force when installing
Suffocation hazard
Keep bag away from babies and children.
Do NOT use in cribs, beds or playpens.  Destroy 
immediately after opening. This bag is NOT a toy.
Failure to do so can result in personal injury and/or death
IMPORTANT:  Use a wall sleeve adapter kit (PXSE) if 
installing a P-Series chassis in a T-Series sleeve.
Compressor
Chassis 
shipping bracket
Shipping pallet
IMPORTANT:  When installing a Friedrich P-Series PTAC into an 
existing sleeve, it is important to ensure that the unit is installed 
completely.  Inspection of the air seal between the condenser air 
baffl es and around the indoor mounting fl ange is recommended.  
In some cases additional gaskets or baffl ing may be required.
Wall sleeve
Weatherboard
Center support
1
Control 
Door
Pins
Front Panel
2
3
Installation Checklist
  
Inspect all components and accessories for damage 
before and after installation.
  
Remove the cardboard wall sleeve support and grille 
weatherboard.
  
Check for proper wall sleeve installation in accordance 
with the wall sleeve installation instructions.
  
Check for a subbase kit or other means of structural 
support which is re quired for ALL installations projecting 
more than 8" into room.
  
Install the recommended Condensate Drain Kits for 
complete con den sate removal.
  
Ensure that the chassis is installed in a 16" high x 42" wide 
wall sleeve that is no deeper than 13 3/4".  A baffl e kit is 
required if the sleeve exceeds that depth.
  
Ensure that drapes, bed, bedspread, furniture, etc. DO 
NOT block either return or discharge air grilles.
  
Inspect the condenser air inlet and outlet for any 
obstructions (shrubbery, etc.)
  
Ensure that 'reset' button is pressed on LCD device (only 
on cord connected models)