Friedrich 920-087-09 ユーザーズマニュアル

ページ / 36
11
FRP012
FOAM
GASKET
OVERFLOW
SLOTS
DETAIL B
DETAIL A
COVER
PLATE
FOAM
GASKET
SCREWS
½” O.D. TUBE
MOUNTING
PLATE
NUT
External Drain (for new  
construction or unit replacement)
When using an external drain system, the condensate is removed through 
either of two drain holes on the back of the wall sleeve.  Select the drain 
hole which best meets your drainage situation and install the drain kit. 
Seal off the other with a cover plate.
Drain Tube Installation (See Figure 12)
1.  Peel the backing tape off the gaskets and apply the sticky side 
to one cover plate and one mounting plate as shown in Details 
A and B.
2.  Place the drain tube through the gasket and the mounting plate 
with the flange toward the wall sleeve.
3.  Attach the drain tube assembly to one of the two drain holes at the 
rear of the wall sleeve.  The large flange on the mounting plate is 
positioned at the bottom of the sleeve facing toward the sleeve, 
Detail B.  When the drain tube is positioned at the desired angle, 
tighten the screws. 
Cover Plate Installation
4.  Mount the foam gasket to the cover plate.  Using two #10 x ½" sheet 
metal screws (provided), attach the cover plate to the remaining 
drain hole.  Make certain the large flange on the plate is positioned 
at the bottom of the sleeve.
5.  Discard the additional cover plate, gasket, machine screws, and 
locknuts.
NOTE: 
The large flange on the mounting plate is positioned at the bottom of the sleeve facing toward the sleeve.  The drain tube must be rotated to a 
horizontal position to allow for the wall sleeve to be installed into the wall.  Once the wall sleeve is installed, return the drain tube to a downward 
angle.
Figure 12 
Drain Kit Installation
NOTICE 
If the wall sleeve has not been installed, the drain tube
must be rotated to a horizontal position until after the
sleeve is installed. Tighten the mounting plate screws
when the tube is in the proper position. Make certain that
the four overflow slots at the rear of the wall sleeve are not
blocked (See Figure 12).
When sealing the sleeve on the outside of the building, be
careful NOT to let the sealant block the two condensate
drain holes or the four overflow slots at the bottom flange
of the sleeve.
Potential property damage can occur if instructions are
not followed.