Friedrich 920-087-09 ユーザーズマニュアル

ページ / 36
13
W ARNING 
15/20A LCDI Device 
30A LCDI Device 
TEST  BEFORE EACH USE 
1. PRESS RESET  BUTT ON 
2. PLUG LCDI INT O POWER   
    RECEPT ACLE 
3. PRESS  TEST  BUTT ON, 
    RESET  BUTT ON SHOULD       
                 POP  UP 
4. PRESS  TEST  BUTT ON,   
    FOR USE 
DO NOT  USE IF  ABOVE  TEST 
F AILS 
WHEN GREEN LIGHT  IS ON 
IT  IS WORKING PROPERL Y 
RESET 
TEST 
W ARNING 
TEST  BEFORE EACH USE 
1. PRESS RESET  BUTT ON 
2. PLUG LCDI INT O POWER   
    RECEPT ACLE 
3. PRESS  TEST  BUTT ON, 
    RESET  BUTT ON SHOULD       
    POP UP 
4. PRESS  TEST  BUTT ON,   
    FOR USE 
DO NOT  USE IF  ABOVE  TEST 
F AILS 
WHEN GREEN LIGHT  IS ON 
IT  IS WORKING PROPERL Y 
RESET 
TEST 
FRP014
A.  Electrical Rating Tables 
All 230/208 volt units are equipped with power cords. 
250V Receptacles and Fuse Types
AMPS
15
20*
30
RECEPTACLE
TIME-DELAY TYPE FUSE 
(or HACR circuit breaker)
15
20
30
  HACR – Heating, Air Conditioning, Refrigeration
*  May be used for 15 Amp applications if fused for 15 Amp
  NOTE:   265 volt units are hard wired.
FUSE/CIRCUIT
BREAKER
Use ONLY type and size fuse or HACR cir-
cuit breaker indicated on unit’s rating plate.  
Proper current protection to the unit is the 
responsibility of the owner.  NOTE: A time 
delay fuse is provided with 265V units.
GROUNDING
Unit MUST be grounded from branch circuit 
through service cord to unit, or through 
separate ground wire provided on per-
manently connected units.  Be sure that 
branch circuit or general purpose outlet is 
grounded.  The field supplied outlet must 
match plug on service cord and be within 
reach of service cord.  Refer to Table 1 for 
proper receptacle and fuse type.  Do NOT 
alter the service cord or plug.  Do NOT use 
an extension cord.
RECEPTACLE
The field supplied outlet must match plug on 
service cord and be within reach of service 
cord.  Refer to Table 1 for proper receptacle 
and fuse type.  Do NOT alter the service 
cord or plug.  Do NOT use an extension 
cord.
All Friedrich 230/208V PTAC units are shipped from the factory with a 
Leakage Current Detection Interrupter (LCDI) equipped power cord.  The 
LCDI device meets the UL and NEC requirements for cord connected air 
conditioners effective August 2004.
To test your power supply cord:
1.  Plug power supply cord into a grounded 3 prong outlet.
2.  Press RESET.
3.  Press TEST ( listen for click; Reset button trips and pops out).
4.  Press and release RESET (listen for click; Reset button latches 
and remains in).  The power supply cord is ready for operation.
NOTE: 
The LCDI device is not intended to be used as a switch.
Once plugged in the unit will operate normally without the need to reset 
the LCDI device.
If the LCDI device fails to trip when tested or if the power supply cord is 
damaged it must be replaced with a new supply cord obtained from the 
product manufacturer, and must not be repaired.
B.  Power Cord Information (230/208V models only)
Figure 14 
Typical LCDI Devices
NOTE: 
Use Copper Conductors ONLY.  Wire sizes are per NEC, check local codes for overseas applications.
Table 1
WARNING 
Electrical Shock Hazard
Turn off electrical power before service
or installation.
ALL electrical connections and wiring
MUST be installed by a qualified
electrician and conform to the National
Code and all local codes which have
jurisdiction.
Failure to do so can result in property
damage, personal injury and/or death.