Heatiator ECO-ADV-WS22 ユーザーズマニュアル
38
Heatilator • ECO-ADV-WS22 • 7057-128C • August 13, 2010
Chimney Flue
Liner
Fireclay
Liner or
Equivalent
Masonry Chimney
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney
Connector
1 inch (25mm) Air
Space to Chimney
Section
Min. Clearance
2 inch (51mm)
Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Chimney Section
Figure 38.1
Solid Pack Chimney with Metal Supports
as a Thimble (Cont’d)
WARNING! Risk of Fire!
Do NOT pack insulation or other combustibles between
Do NOT pack insulation or other combustibles between
spacers.
• ALWAYS maintain specified clearanes around
• ALWAYS maintain specified clearanes around
venting and spacers and install spacers as specified.
Failure to keep insulation or other material away from
vent pipe may cause a fire.