Heatilator • ECO-ADV-WS22 • 7057-128C • August 13, 2010
A. Outside Air Kit Installation
Instructions
1.
Rear: Remove the access cover on the back of the pedestal
and discard.
Figure 39.2.
2.  Using a #2 Phillips screw driver attach the flex adapter to
the appliance using 4 screws. Secure with wire tie.
Figure 
39.1.
3.
Floor:  For standard floor installation remove the circular
“knock-out” in the base of the pedestal.
4.
Floor & Rear Installation: Cut a 4 inch (102mm) hole in out-
side wall or floor to accommodate outside air piping. Use 4 inch
(102mm) aluminum metal flex or rigid piping to directly connect
outside air to appliance intake. Use the supplied termination
cap with a rodent screen. Seal between the wall (or floor) and
the pipe with silicone to prevent moisture penetration.
Included in kit:  Termination cap, (2) wire ties, flex adapter,
and fasteners
Items Needed for Installation (not supplied)
 •  4  inch  flex  aluminum  pipe,  or  if  using  alternate  material,
then it shall be made from durable, non-combustible, heat
resistant material up to 350
o
F (177
o
C). Cut the pipe to the
required length for your installation.
 • Phillips head screw driver
 • Silicone sealant
 • Non-combustible pedestal sealing material if installing with
the Alternate Floor configuration.
•  Drills and saws necessary for cutting holes through the wall
or flooring in your home
Figure 39.1 - Floor & Rear Installation
A source of air (oxygen) is necessary in order for combustion to
take place. Whatever combustion air is consumed by the fire
must be replaced.
Air  is  replaced  via  air  leakage  around  windows  and  under
doors. In homes that have tightly sealed doors and windows,
an outside air source is highly recommended. An optional Out-
side Air Kit is available.
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination 
Cap
For Floor Installa-
tions Remove 
Circular “Knock-Out” 
in Base of Pedestal.
Wire Tie
9
Appliance Set-up
WARNING! Risk of Fire and Asphyxiation!
Do not draw outside combustion air from:
•  Wall, floor, ceiling cavity or enclosed space such
as an attic or garage. Also do not draw outside air
from close proximity to exhaust vents or chimneys.
Fumes or odor may result if you do.
Outside air inlet must be located to prevent blockage
from leaves, snow, ice or other debrs. Blockage may
cause combustion air starvation. Smoke spillage may
set off alarms or irritate sensitive individuals.
The length of the outside air supply duct shall NOT
exeed the length of the vertical height of the exhaust
flue.
•  The fire will not burn properly and their will be
smoke spillage when the door is opened due to air
starvation.
Remove Circular “Knock-Out” in Base of 
Pedestal and Seal the Pedestal with Non-
combustible Material.
Sealing Material 
(not supplied)
5.
Floor  Installation Alternative:    In  some  instances
you may not be able to install the flex pipe as show in
Figure 39.1.
If  that  is  the  case,  follow  the  instructions  for  a  rear
installation install the flex pipe to the rear of the ped-
estal and remove the circular “Knock-Out” in the base
of the the pedestal. You must seal off the pedestal
with  non-combustible  material  (not  supplied).   The
goal is to seal the pedestal so no room air can leak
into the pedestal and to seal for cold air infiltration.
Figure 39.2.
Figure 39.2 - Alternate Floor Installation