Regency FG39-LPG ユーザーズマニュアル

ページ / 36
12
Regency FG39 FireGenie Freestanding Gas Stove
Pipe Length
Round Support
Box/Wall Thimble
(Part # 940)
Round
Support Box/
Wall Thimble
(Part # 940)
Vertical
Terminal
Storm Collar
Part # 953
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
24" (610mm)
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
90 Elbow
o
Wall Thimble
Part # 942
Vinyl Siding
Standoff (Optional)
Part #950
AstroCap
Termination Cap
(Part# 946-523)
DURA-FLUE
TERMINATION  KIT
Planning Your Dura-Flue
Installation
There are two basic types of Dura-Flue Room
Sealed System installations: horizontal termi-
nation  and  vertical  termination.  Confirm  the
maximum horizontal run and maximum vertical
rise from the diagrams on page 9.
When planning your installation, it will be nec-
essary to select the proper length of flue pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness.  (The wall
thimble is suitable for 2 x 4 or 2 x 6 / .6m x 1m
or  .6m  x  2m  wall  construction.)  Select  the
amount of vertical rise desired for "vertical-to-
horizontal" type installations.
Warning:  Always maintain required clear-
ances  (air  spaces)  to  nearby  combusti-
bles to prevent a fire hazard. Do not fill air
spaces  with  insulation.
The minimum clearance requirements between
the  outer  wall  of  the  flue  pipe  and  nearby
combustible surfaces is 1-1/4 inch. Be sure to
check the flue termination clearance require-
ments from decks, windows, soffits, gas reg-
ulators, air supply inlets and public walkways
as  specified  in  the  Exterior  Flue  Termination
Locations on page 8 and in your local building
codes.
To determine the length of flue pipe required for
vertical installations, measure the distance from
the  unit  flue  outlet  to  the  ceiling,  the  ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For  multi-storey  applications,  fire  stops  are
required  at  each  floor  level.  If  an  offset  is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
One 90
o
 for horizontal terminations and two 45
o
for vertical termination.
DURA-FLUE FLUING
COMPONENTS
You will require the following components with
your new Regency Room Sealed Freestanding
Gas Stove. Please review your product to make
sure you have everything you need. In the eflue
that  you  are  missing  any  part,  contact  your
dealer.
Note: These  are  the  minimum  pieces
required.  Other  parts  may  be  re-
quired  for  your  particular  instal-
lation.  See  below  for  a  list  of  flue
parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is not
recessed into siding.
The vinyl siding standoff is required for walls
with  vinyl  siding.
Minimum  components  for  a  Dura-Flue
Horizontal  Installation:
A) Dura-Flue Horizontal Termination Kit
B) Wall Thimble (required  for combus-
tible  walls)
Minimum  components  for  a  Dura-Flue
Vertical  Termination:
C) Dura-Flue Vertical Termination Kit
The Simpson Dura-Flue Room Sealed System
offers a complete line of component parts for
installation of both horizontal and vertical instal-
lation.  Many  items  are  offered  in  decorative
black, as well as galvanized finish. The galva-
nized pipe and fittings are used for concealed
INSTALLATION
locations such as attics or where corrosion is
a factor, such as above the roof line. Decora-
tive brass trim kits are available for both wall
thimbles and ceiling support boxes.
Part #
    Description
971
Horiz. Termination Kit includes: 90
o
black elbow, wall thimble cover,
horiz. square termination cap, 24"
black pipe, 11" -14" 5/8" adjustable
black  pipe
970
Basic Horiz. Termination Kit
includes:  90
o
 black elbow, wall
thimble cover, horiz.  square
termination cap
978
Vert. Termination Kit includes
0/12 -  6/12 pitch adjustable
flashing, storm  collar, low profile
term. cap
908B
6" (152mm) Pipe Length-Black
907B
9" (229mm) Pipe Length-Black
906
12" (304mm) Pipe Length Galv.
906B
12" (304mm) Pipe Length-Black
904
24" (610mm) Pipe Length Galv.
904B
24" (610mm) Pipe Length-Black
903
36" (914mm) Pipe Length Galv.
903B
36" (914mm) Pipe Length-Black
902
48" (1219mm) Pipe Length Galv.
902B
48" (1219mm) Pipe Length-Black
911B
11"-14 5/8" (219mm - 372mm)
Adj. Pipe Length-Black
917B
17"- 24" (432mm - 610mm)
Adj. Pipe Length Black
945
45
Elbow Galv.
945B
45
O
  Elbow-Black
945G
45
Elbow-Swivel  Galv.
990G
90
Elbow-Swivel  Galv.
Dura-Flue Basic
Horizontal Kit # 970
1 90
o
  Elbow
1 Wall Thimble Cover
1 Astro Cap