 U39 ULTIMATE Direct Vent Freestanding Gas Stove
27
GAS PIPE PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut-off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig. (3.45 
kPa).  Disconnect piping from valve at pressures 
over 1/2 psig.
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS
FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 730-920  
Contains:
Qty. Part #  Description
1  904-240  Burner Orifi ce #37 (Natural Gas)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033  Instruction Sheet
Propane Conversion Kit 730-922
Contains:
Qty. Part #  Description
1  904-390  Burner Orifi ce #52 (Propane)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033  Instruction Sheet
Additional Piece (pkg. with unit): 
1   
Log Bracket Restrictor
1)  Shut off the gas supply.
2)  Open the front door.  Carefully remove the 
logs and lava rock.
3)  Remove burner. See diagram below.
Burner Orifi ce
4)  Unscrew the 2 Rear 
Log Pins and move 
to the front hole 
position.
 
5)  Remove Rear Log 
Bracket and slide 
the Log Bracket 
Restrictor between 
the Rear Log Bracket 
Position the Log Bracket Restrictor between  
the Rear Log Bracket and the burner.
6)  Remove burner orifi ce  with a 1/2" wrench 
and discard.
The manifold pressure is controlled by a regulator 
built into the gas control, and should be checked 
at the pressure test point.
Note:    To properly check gas pressure, both 
inlet and manifold pressures should 
be checked using the valve pressure 
ports on the valve.
1)  Make sure the valve is in the "OFF" 
position.
2)  Loosen the "IN" and/or "OUT" pressure 
tap(s), turning counterclockwise with a 1/8" 
wide fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" 
pressure tap(s) using a 5/16" ID hose.
4)  Light the pilot and turn the valve to "ON" 
position. Read manometer.
5)  The pressure check should be carried out 
with the unit burning and the setting should 
be within the limits specifi ed on the safety 
label.
6)  When fi nished reading manometer, turn 
off the gas valve, disconnect the hose and 
tighten the screw (clockwise) with a 1/8" fl at 
screwdriver. Note: Screw should be snug, 
but do not over tighten
7)  Reinstall new burner orifi ce (NG stamped 
#37 or LP stamped #52) and tighten.
8)  Reverse steps 3) and 2).
9)  Adjust Vent restrictor setting: To set the 
Vent restriction as indicated in the diagram, 
simply loosen the screws and push the vent 
restrictor plate to the correct position. Tighten 
the screws.
 
 Unit Btu/h 
Restrictor 
Opening
 U39 38,000 
1-3/4" 
(44mm)
  
  30,000 
1-1/4" 
(32mm)
Note: Use a 
magnetic type 
screwdriver if 
possible.
and the burner, secure with the 2 screws.
Vent Restrictor set-
ting at High Btu/h
Vent Restrictor set-
ting at Low Btu/h
10) Attach the label  "This unit has been 
converted to..." on top of the Serial # decal 
over the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of fl ame control.  Check 
for proper fl ame appearance and glow on 
logs. 