AERATION 
ADJUSTMENT
The burner aeration is factory set but may need 
adjusting due to either the local gas supply or 
altitude.
 
 
U39 with 38,000 Btu/h
U39-NG1 
Natural Gas:  
1/4" open
U39-LP1 Propane: 
  1/2" 
open
U39 with 30,000 Btu/h
U39-NG1 Natural 
Gas 3/16" 
open
U39-LP1 Propane 
3/8" 
open
The aeration adjustment gears are located on 
the right side of the burner box and can be 
accessed from the side or from the front when 
the louvers are removed.
To adjust the aeration: use the allen key to turn 
the turning gear which will adjust the air shutter. 
Open the air shutter for a blue fl ame or close it 
for a yellower fl ame. 
Caution: Carbon will be produced if the air 
shutter is closed too much.
Note: Any damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
Note:  Aeration Adjustment should only be 
performed by an authorized Regency
®
 
Installer at the time of installation or 
service.
INSTALLATION
Clockwise to open,
counter-clockwise to close.
Valve Description
1) Gas 
on/off 
knob
2) Manual 
high/low 
adjustment
3) Pilot 
Adjustment
4) Thermocouple 
Connection
5) Main 
Operator
6)  Outlet Pressure Tap (Manifold Pressure)
7)  Inlet Pressure Tap (Supply Pressure)
8) Pilot 
Outlet
9)  Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole