Listen Technologies CU 6010 ユーザーズマニュアル

ページ / 39
Danish Interpretation Systems 
 
User Manual 
 
Manual 01 18 04438
 
25 
Maximum number of units to be connected    
The following table shows the maximum number of 
units,  which  can  be  connected  to  each  of  the  four 
outputs 
(A1,  A2,  B1  or  B2) 
on  a  CU  6010/6011 
Central  Unit  or  on  each  output  on  an  EX  6010 
Extension Unit or on the output of a PS 6000.. 
CM/DM 60x0P Chairman/Delegate Units – CU 6010/6011 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of  inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of CM/DM 
60x0P pr output 
10 m 
1 m 
51 m 
42 
30 m 
1 m 
67 m 
38 
50 m 
1 m 
83 m 
34 
100 m 
1 m 
122 m 
23 
150 m 
1 m 
165 m 
16 
10 m 
2 m 
88 m 
40 
30 m 
2 m 
98 m 
35 
50 m 
2 m 
108 m 
30 
100 m 
2 m 
140 m 
21 
150 m 
2 m 
178 m 
15 
CM/DM 60x0P Chairman/Delegate Units – CU 6005 
The following table shows the maximum number of 
units,  which  can  be  connected  to  the  two  outputs 
(A1 and A2) simultaneously on a CU 6005 in total  
If  only  one  chain  is  used  the  information  in  the 
above table must be used. 
   
Length of Feeding Cable 
Type CAT5 AWG24  
Length of  inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of CM/DM 
60x0P for both outputs 
10 m 
1 m 
2x32 m 
2x23 
30 m 
1 m 
2x51 m 
2x22 
50 m 
1 m 
2x70 m 
2x21 
100 m 
1 m 
2x117 m 
2x18 
150 m 
1 m 
2x164 m 
2x15 
10 m 
2 m 
2x54 m 
2x23 
30 m 
2 m 
2x72 m 
2x22 
50 m 
2 m 
2x88 m 
2x20 
100 m 
2 m 
2x132 m 
2x17 
150 m 
2 m 
2x176 m 
2x14 
CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011 
This  configuration  shows  two  CM/DM  60x0P 
Delegate/Chairman Units connected to one JB 6002 
Junction  Box  with  3m  cables  between  each  JB 
6002.  
Maximum  5  m  cable  from  JB  6002  to  CM/DM 
60x0  and  maximum  one  CM/DM  60x0  on  each 
output of JB 6002.