12-2
Chapter 12: Parameters
12
12-2 Details of each of the parameters
(1) Enable/disable the use of the transmission buffer (Setting parameter address 37
(8)
)
Select whether to enable/disable the buffer for each message by entering the appropriate value at
parameter address 37
(8)
.
* 80 to 83
(H)
 are the valid values for parameter address 37
(8)
.
 Relationship between messages and transaction codes.
(2) Token monitor time (parameter address 04
(8)
)
Set the token monitor time as follows, based on the number of bytes being sent by this station.
- 0 to 5K bytes: 10 ms
- 5K to 10K bytes: 30 ms
- 10K bytes or more: 40 ms
Message
Selection of
transmission buffer
80
(H)
81
(H)
82
(H)
83
(H)
Message other than transmission
×
×
Transmission
message
Messages other than SHARP's proprietary
message format
SHARP's
proprietary format
Computer link function
Remote function
×
×
Message
Transaction code (TCD)
Use selection of
transmission type buffer
80
(H)
81
(H)
82
(H)
83
(H)
Messages
other than
transmission
60000 to 65202 (request)
X
X
X
X
65203 to 65215 (response)
X
O
X
O
Transmission
messages
0 to 999
O
O
O
O
1000 (request computer link function: SHARP's
proprietary function)
X
X
O
O
1001 (request remote function: SHARP's proprietary
function)
X
X
O
O
1002 to 1199
O
O
O
O
1200 (response of computer link function: SHARP's
proprietary function)
O
O
O
O
1201 (response of remote function: SHARP's
proprietary function)
X
X
O
O
1202 to 59999
O
O
O
O
*
(Transmission buffer... 
: Used, 
×
: Not used)
*
(Transmission buffer... 
: Used, 
×
: Not used)