Chapter 12: Parameters
12
Switch SW3 setting
0
1
2
3
4
Parameter address
(8)
(system memory)
#0300 to
#0377
#1400 to
#1477
#1500 to
#1577
#1600 to
#1677
#1700 to
#1777
Connection cable
(ZW-3KC)
JW-14PG
Control module (JW-100CUH)
JW-50FL
(The modules shown below 
are installation examples)
FL-net module
Host PC
Control module
JW-50FL
JW50H
JW-50CUH
JW70H
JW-70CUH
JW100H
JW-100CUH
Read parameter 
address 77
(8)
 (system 
memory #0377 *).
* When switch SW3 is 
set to 0.
Decimal display of the setting
   #0301
DCM
168
   #0302
DCM
250
P   System
>#0303
DCM
003
   #0375
HEX
00
   #0376
HEX
00
P   System
>#0377
HEX
00
JW-14PG screen
[
2
] When the JW-50FL is used
Set the parameters for the JW-50FL in the system memory of the control module. Select the
parameter (system memory) area using the SW3 switch on the JW-50FL.
(Details 
 See the next page. Switch SW3 
 See page 4-4.)
Note: Do not set switch SW3 outside the range of 0 to 4.
- Relationship between the host PC and the control module
- How to set the parameters using the JW-14PG
This paragraph describes param-
eter setting procedures (in system
memory) using the handheld JW-
14PG programmer.
1
 Connect the JW-14PG to the
support tool connector on the
control module.
2
 Set the PC to program mode.
3
 Set  a start switch to 00
(H)
.
4
 Enter the IP address (192.168.250.3) at parameter addresses 00 to 03
(8)
.
Same as the above, enter the other parameter addresses.