469
Execution Conditions
Commands
Responses
Single
Multiple
Single
Multiple
OK
OK
OK
---
End Codes
An end code of 14 (format error) will be returned if the length of the command is
incorrect or the first word of write data isn’t in the first frame.
An end code of 15 (entry number data error) will be returned if the specified write
data exceeds the data area boundary, the beginning word isn’t specified in BCD,
or the write data isn’t hexadecimal. (An end code of A5 will be returned instead of
15 for non-hexadecimal write data in multiple command frames.)
With Host Link Units, an end code of 15 (entry number data error) will be re-
turned if the write data isn’t BCD.
End code
Contents
00
Normal completion
01
Not executable in RUN mode
13
FCS error
14
Format error
15
Entry number data error
18
Frame length error
A3
Aborted due to FCS error in transmit data
A4
Aborted due to format error in transmit data
A5
Aborted due to entry number data error in transmit data
A8
Aborted due to frame length error in transmit data
10-3-13
TC STATUS WRITE –– WG
Writes the status of the Completion Flags for timers and counters in the TC area,
starting from the specified timer/counter (number). Writing is done number by
number. When a Completion Flag is ON, it indicates that the time or count is up.
Command Format
@      
W
G
FCS
x 10
1
x 10
0
x 10
3
x 10
2
x 10
1
x 10
0
Node no.
Header
code
Write data 
(1 timer/counter)
Write data 
(for number of TC to write)
Beginning timer/counter
(0000 to 0511)
Terminator
ON/
OFF
Response Format
@
W
G
x 10
1
x 10
0
x 16
1
x 16
0
FCS
Node no.
End code
Header
code
Terminator
PC Settings
PC Mode
UM Area
RUN
MONITOR
PROGRAM
Write-protected
Read-protected
---
OK
OK
OK
OK
Execution Conditions
Commands
Responses
Single
Multiple
Single
Multiple
OK
OK
OK
---
Host Link Commands