Zebra Technologies 2237A10L010 ユーザーズマニュアル

ページ / 230
Data Ports
Applicator Interface Connector
184
13383L-004 Rev. A
Xi
IIIPlus/R110Xi/R170Xi User Guide
9/6/07
5
PAUSE
Input
To toggle the current Pause state, this input must be 
asserted LOW for 200 milliseconds, or until the 
SERVICE REQUIRED output (pin 10) changes state.
6
REPRINT
Input
• If the Reprint feature is enabled, this input must be 
asserted LOW to cause the printer to reprint the last 
label.
• If the Reprint feature is disabled, this input is ignored.
7
+28 V
(For the 5V board, 
+28V is fused at 2 A. 
For the 24–28V 
board, +28V is fused 
at 500 mA.)
Caution • 
Replace 
the fuse only with 
one of the same 
type and rating.
Power
The Interface Power Supply. Supplies power to external 
sensors as required.
Note • 
If operating with 28V signals only, pin 7 
may be used to supply power to pin 2, which 
creates a non-isolated mode of operation. (This is 
applicable for all printers except the 
110XiIIIPlus.)
8
POWER GROUND
(+28 V DC Return)
Ground
The Interface Power Ground.
Note • 
If pin 7 is used to supply power to pin 2, 
use this pin to ground pin 1. (This is applicable for 
all printers except the 110XiIIIPlus.)
9
No function.
10
SERVICE 
REQUIRED
Output
Asserted LOW in the following circumstances:
• the printhead is open
• the ribbon or media is out
• the printer is paused 
• an operational fault occurs
• a Resynch error occurs while the applicator Resynch 
mode is set to Error mode (see 
)
Table 22 • Applicator Interface Connector Pin Configuration (Continued)
Pin 
No.
Signal Name
Signal Type
Description
* Applicator boards have separate part numbers for the +5V version (49872-099M) and the +24-28V version (33361-099M).