Data Ports
Applicator Interface Connector
9/6/07
Xi
IIIPlus/R110Xi/R170Xi User Guide
13383L-004 Rev. A
11
END PRINT
Output
See 
 for more information 
about the start and end print signals. See 
 for more information about the 
modes.
• MODE 0—The applicator port is OFF.
• MODE 1—Asserted LOW only while the printer is 
moving the label forward; otherwise deasserted HIGH.
• MODE 2—Asserted HIGH only while the printer is 
moving the label forward; otherwise deasserted LOW.
• MODE 3—(Default) Asserted LOW for 20 
milliseconds when a label is completed and positioned. 
Not asserted during continuous printing.
• MODE 4—Asserted HIGH for 20 milliseconds when a 
label is completed and positioned. Not asserted during 
continuous printing.
12
MEDIA OUT
Output
Asserted LOW while there is no media in the printer.
13
RIBBON OUT
Output
Asserted LOW while there is no ribbon in the printer.
14
DATA READY
Output
See 
 for more information 
about this signal.
• Asserted LOW when sufficient data has been received 
to begin printing the next label.
• Deasserted HIGH whenever printing stops after the 
current label, due to either a pause condition or the 
absence of a label format.
15
(Non-
RFID)
SPARE 
Output
To be determined.
15 
(RFID)
VOID
Output
• Asserted LOW when the RFID transponder over the 
antenna is “voided.”
• Deasserted HIGH when the end print signal is asserted.
Table 22 • Applicator Interface Connector Pin Configuration (Continued)
Pin 
No.
Signal Name
Signal Type
Description