The control register (TACR) is laid out as shown in Table 11-4.
The Timer A Prescale Register (TAPR) specifies the main clock for Timer A. This will 
affect all of the timer A countdown timers. By default Timer A is clocked by peripheral 
clock divided by two.
The prescale register (TAPR) is laid out as shown in Table 11-5.
Table 11-4.  Timer A Control Register
Timer A Control Register 
(TACR)
(Address = 0x00A4)
Bit(s)
Value
Description
7
0
Timer A7 clocked by the main Timer A clock.
1
Timer A7 clocked by the output of Timer A1.
6
0
Timer A6 clocked by the main Timer A clock.
1
Timer A6 clocked by the output of Timer A1.
5
0
Timer A5 clocked by the main Timer A clock.
1
Timer A5 clocked by the output of Timer A1.
4
0
Timer A4 clocked by the main Timer A clock.
1
Timer A4 clocked by the output of Timer A1.
3
0
Timer A3 clocked by the main Timer A clock.
1
Timer A3 clocked by the output of Timer A1.
2
0
Timer A2 clocked by the main Timer A clock.
1
Timer A2 clocked by the output of Timer A1.
1:0
00
Timer A interrupts are disabled.
01
Timer A interrupts use Interrupt Priority 1.
10
Timer A interrupts use Interrupt Priority 2.
11
Timer A interrupts use Interrupt Priority 3.
Table 11-5.  Timer A Prescale Register
Timer A Prescale Register 
(TAPR)
(Address = 0x00A1)
Bit(s)
Value
Description
7:1
These bits are ignored.
0
0
The main clock for Timer A is the peripheral clock.
1
The main clock for Timer A is the peripheral clock divided by two.