Chapter 4 – Command Line Interface (CLI) 
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
37
 
Serial Commands – Setup 
 
Command Syntax 
set serial [s1] modem dialing-trig-mode <none/dtr/command> 
Description 
Sets the dialing trigger mode for the modem port S1. 
If dialing trig mode is none: 
    The serial interface will initialize the modem and dial as per the configured 
parameters. 
If dialing trig mode is dtr: 
    As soon as a serial device is connected to S0 (DTR goes high), the S1 
serial interface will initialize the modem and dial as per the configured 
parameters. 
If dialing trig mode is command: 
    The serial interface will dial only on demand. The possible commands that 
can trigger the link are:  
• 
"linkup s1" command is issued 
• 
Application trigger (SMTP, POP3 Client, etc) 
Note:
 This command triggers a reboot upon save.  
Default Value 
Command 
Success 
OK 
Error 
1.  Too few arguments 
 
"Usage: set serial s1 modem dialing-trig-mode <none/dtr/command> 
     Type 'set serial s1 modem dialing-trig-mode ?' for more information" 
2. Invalid string 
     "error: Invalid string 
Type 'set serial s1 modem dialing-trig-mode ?' for more information" 
 
 
Command Syntax 
set serial s1 modem country-code <value> 
Description 
Sets the modem country code value to <value>. 
This command is valid only for  port S1.  
Default Value 
Success 
OK 
Error 
1.  Too few arguments 
 
“Usage: set serial s1 modem country-code value <value> 
     Type ‘set serial s1 modem country-code value ?’ for more information” 
 
Command Syntax 
set serial [s0/s1] modem hangup-string <hangup-str> 
Description 
Sets the Modem hang-up string. 
Triggers for a reboot upon save. 
Default Value 
+++ATH0 
Success 
OK 
Error 
1.  Too few arguments 
 
"Usage: set serial s0/s1 modem hangup-string <hang-str> 
 