DELL 8132 ユーザーズマニュアル

ページ / 1818
908
FIP Snooping Commands
Default Configuration
This command has no default configuration.
Command Mode
User EXEC or Privileged EXEC mode
User Guidelines
This command has no user guidelines.
Example
(switch)# show fip-snooping
Global Mode:   Enable
FCoE VLAN List :   2,4,5-8
FCFs:   2
ENodes:   2
Parameter
Description
Global Mode
FIP snooping configuration status on the switch. It displays 
Enable when FIP snooping is enabled on the switch and 
Disable when FIP snooping is disabled on the switch.
FCoE VLAN List
List of VLAN IDs on which FIP snooping is enabled.
FCFs
Number of FCFs discovered on the switch.
ENodes
Number of Enodes discovered on the switch.
Sessions
Total virtual sessions on the switch.
Max VLANs
Maximum number of VLANs that can be enabled for FIP 
snooping on the switch.
Max FCFs in VLAN Maximum number of FCFs supported in a VLAN.
Max ENodes
Maximum number of ENodes supported in the switch.
Max Sessions
Maximum number of Sessions supported in the switch.
2CSPC4.X8100-SWUM102.book  Page 908  Friday, March 15, 2013  8:56 AM