DELL 8132 ユーザーズマニュアル

ページ / 1818
FIP Snooping Commands
907
User Guidelines
It is recommended that FCF-facing ports be placed into auto-upstream mode 
in order to receive DCBX information and propagate it to the CNAs on the 
downstream (host-facing) ports.
Interfaces enabled for PFC should be configured in trunk or general mode 
and must be PFC-operationally enabled before FCoE traffic can pass over the 
port.
This command can only be entered after FIP snooping is enabled using the 
 command. Otherwise, it does not appear in the CLI 
syntax tree.
Example 
The following example configures an interface to be connected to an FCF 
switch.
(config)# interface te1/0/1
(config-vlan)# fip-snooping port-mode fcf
show fip-snooping
Use the show fip-snooping sessions command in User EXEC or Privileged 
EXEC mode to display information about the global FIP snooping 
configuration and status.
Syntax
show fip-snooping
Default Configuration
This command has no default configuration.
Command Mode
User EXEC, Privileged EXEC, Config mode and all Config sub-modes
User Guidelines
The following information is displayed.
2CSPC4.X8100-SWUM102.book  Page 907  Friday, March 15, 2013  8:56 AM